Department Code; Distinguish Thin Lines - Toshiba e-Studio 352 Printing Manual

Hide thumbs Also See for e-Studio 352:
Table of Contents

Advertisement

7 Printing from UNIX
Option Value
private=din
If this option is not specified, the printer's default value will be used.
A private printing job requires the user to enter a maximum number of 63 character long string.
Character lengths longer than 63 will be clipped to 63.
The following characters are invalid, but no type checking is carried out.
"& ' ( ) ; < > ˆ ` | ~

Department Code

The department access code can be set using the following option.
Option Value
dept=code
How the equipment performs printing for an invalid department code print job, which no depart-
ment code or invalid department code is specified, varies depending on the Department Code
Enforcement setting that can be set from TopAccess Administrator mode. When the Depart-
ment Code Enforcement is set to "ON", the invalid department code print job will be stored in the
invalid department code print job list without printing. When the Department Code Enforcement
is set to "Print", the invalid department code print job will be printed. When the Department
Code Enforcement is set to "Delete", the invalid department code print job will be deleted without
printing.
Smoothing
The smoothing mode can be set using the following option.
Option Value
smoothing=on
smoothing=off
Example: The command to set the smoothing mode is "lp -o smoothing=on filename".

Distinguish Thin Lines

The thin line limit mode can be set using the following option.
Option Value
thinlinelimit=on
thinlinelimit=off
Example: The command to set the thin line limit mode is
"lp -o thinlinelimit=on filename".
314
Printing from an Application
Alternate
Value
Process as a private print job. The din is up to 63-digit
(between 1 to 63) password.
Alternate
Value
Set the department access code. The code is a 5-digit
numeric value.
Alternate
Value
ON
Set the smoothing mode.
OFF
Cancel the smoothing mode.
Alternate
Value
ON
Set the thin line limit mode.
OFF
Cancel the thin line limit mode.
Description
Description
Description
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio 452E-studio 282E-studio 232E-studio 202l

Table of Contents