To unmount indoor unit
(1) Remove the screw cover on the bottom surface.
(Fig. 1-176)
(2) Fasten the frame to the rear panel using the 2 supplied
tapping screws 5/32 × 13/32" (4 × 10 mm). (Fig. 1-176)
(3) Press the 2
marks on the lower part of the indoor unit
and unlatch the tabs. Then lift the indoor unit and unmount.
(Fig. 1-177)
NOT E
Under normal conditions, the installation design calls for a
less than 2 mm gap between the air conditioner unit and the
wall.
Confirm that the gap is appropriate (less than 5/64" (2 mm)).
6-54. Drain Hose
a)
The drain hose should be slanted downward to the
outdoors. (Fig. 1-178)
b)
Never form a trap in the course of the hose.
c)
If the drain hose will run in the room, insulate the hose with
insulation* so that chilled condensation will not damage
furniture or floors. (Fig. 1-179)
*Foamed polyethylene or its equivalent is recommended.
Do not supply power to the
unit or operate it until all
WARNING
tubing and wiring to the
outside unit are completed.
Risk of Electric Shock
Screw
cover
Indoor
unit
Insulation material
(Locally purchased)
must be used.
1-169
1. Specifications
Screw
Fig. 1-176
Push
Fig. 1-177
Slant
Drain
hose
Fig. 1-178
Condensation
Fig. 1-179
1