Download Print this page
Panasonic 42PSU1U6 Quick Manual
Panasonic 42PSU1U6 Quick Manual

Panasonic 42PSU1U6 Quick Manual

Split system submittal data ceiling recessed air conditioner

Advertisement

Quick Links

Split System Submittal Data
Ceiling Recessed Air Conditioner
System: 42PSU1U6
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
V/PH/Hz
Circuit Ampacity
(A)
Fuse Size, Max.
(A)
Compressor
No. used
R.L. Amps - L.R.
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
No. Motors
(High)
CFM
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
(sq.ft.)
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
(RPM, High)
No. Motors
(HI/Med/Lo)
CFM
Indoor Sound Rating
(Hi) (dB-A)
F.L. Amps
Coil Type
Aluminum Plate Fin & Copper Tube
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
(in.)
Drain Connection Size
Indoor/Outdoor: S-42PU1U6/U-42PS1U6
Grille: CZ-36KPU1U
General Data (at 230V)
230/208/1/60
15-40 Indoor-Outdoor
15-40 Indoor-Outdoor
DC Rotary Inverter
(A)
18.1-31
Propeller
18-7/64-2
DC Motor
(RPM)
(W)
(A)
Aluminum Fin & Copper Pipe
Slit Plate - Inner Rifl ed
2 - 12.7
(in.)
17-7/16-1
3 & Auto
(W)
1050/840/720
(A)
Slit Plate - Inner Rifl ed
(sq.ft.)
(in.)
1-17/64
Approval:
Date:
Construction:
Unit #:
Drawing #:
Refrigerant
Lbs. - R410a (outdoor unit)
Control
1
Connection
Line Length, Max (ft.)
Lift Diff erence, Max (ft.)
Line Size
Line Size
Dimensions
Indoor Unit
8 - 830
1 - 90
3531
Outdoor Unit
19.7
Weight
Net
Shipping
11.62
3/8"
Shipping Volume
Turbo
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity
6-506
Sensible Capacity
1 - 60
Latent Capacity
SEER
Dehumidifi cation
45
1.0
Amps
Power Inputs
Outdoor Sound Rating
2-14.9
8.2
9/32"
Electric Expansion Valve
50 (outdoor lower), 100 (outdoor higher)
(in. O.D. Discharge)
(in. O.D. Suction)
(in.)
(Uncrated)
14-31/64 x 45-9/32 x 33-55/64
(Crated)
12-13/32 x 44-19/64 x 33-9/32
(Uncrated)
48-7/16 x 37 x 13-3/8
(Crated)
52-3/8 x 39-31/32 x 16-3/32
Indoor
(lbs.)
60
(lbs.)
71
Indoor
(cu.ft.)
10.6
(BTU/H)
39,500 (9,500-39,500)
(BTU/H)
(BTU/H)
(Pints/H)
(A)
(W)
(dB-A)
R410A
7.94
Flare
165
3/8"
5/8"
H x W x D
Outdoor
220
240
Outdoor
19.5
23,530
15,970
14.6
12.6
23.0/25.4
4,520/4,520
53

Advertisement

loading
Need help?

Need help?

Do you have a question about the 42PSU1U6 and is the answer not in the manual?

Questions and answers

Summary of Contents for Panasonic 42PSU1U6

  • Page 1 Split System Submittal Data Ceiling Recessed Air Conditioner System: 42PSU1U6 Indoor/Outdoor: S-42PU1U6/U-42PS1U6 Grille: CZ-36KPU1U Job Name: Approval: Location: Date: Engineer: Construction: Submitted to: Unit #: Submitted by: Drawing #: Reference: General Data (at 230V) Power V/PH/Hz 230/208/1/60 Circuit Ampacity 15-40 Indoor-Outdoor Fuse Size, Max.
  • Page 2 Dimensions Features Options Available Controls Refrigerant Line Set Microprocessor Remote Controller Fresh Air Intake Available LCD Wired Type, Temp. Sensor Built In Knock - out Temperature Control Airduct Extension IC Thermostat Timer Condensate Drain Pump Standard 72 Hr. ON/OFF Night Setback Wireless Remote Controller Available Built-In...

This manual is also suitable for:

S-42pu1u6Cz-36kpu1uU-42ps1u6