Gas Line Installation - Marquis Solace MQHBZDV3636 Installation Instructions Manual

Zero clearance vented gas fireplace heater
Hide thumbs Also See for Solace MQHBZDV3636:
Table of Contents

Advertisement

This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/CGA -
B149.1 or .2 installation codes for Gas Burning appliances and equipment in Canada and the National Fuel Gas Code ANSI Z223 in the
U.S.A.
1. The gas pipeline can be brought in through
either the right or the left side of the appliance.
A knockout is provided at either location
to allow for the gas pipe installation and
testing of any gas connection.
2. The gas control inlet is 3/8" NPT. Typical
installation layout for rigid pipe is shown at
right.
3. When using copper or flex connector, use
only approved fittings. Always provide a
union so that gas line can be easily
disconnected for burner or fan servicing. See
gas specification for pressure details and ratings.
4. When a vertical section of gas pipe is
required for the installation, a condensation trap is needed. See CAN/CGA-B149.1 or .2 for code details.
5. For natural gas, a minimum of 3/8" iron pipe with gas minimum pressure of 4.5" w.c. must be used for supply from the
gas meter. Consult with the
local gas utility if any questions arise concerning pipe sizes.
6. A 1/8" NPT plugged tappings are accessible for test gauge connection both on the inlet and outlet of the gas valve.
7. Turn the gas supply ON and check for leaks. DO NOT USE OPEN FLAME FOR THIS PURPOSE. Use an approved
leak testing solution.
8. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at
test pressures in excess of 1/2 PSIG (3.5 KPa).
9. The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any
pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.5 KPa).
Note: The gas line connection may be made of 1/2" rigid pipe or an approved flex connector. Since some
municipalities have additional local codes, it is always best to consult your local authorities and the current
CAN/CGA - B149.1 or .2 installation code in Canada or the National Fuel Gas code ANSI Z223.1 in the U.S.A.
For the state of Massachusetts a T-handle gas shut-off
valve must be used on a gas appliance. This T-handle gas
shut-off valve must be listed and approved by the state of
Massachusetts. This is in reference to the state of
Massachusetts state code CMR238.
Gas Specifications
Models
Fuel
Gas Control
Maximum Input HI [Btu/hr]
Maximum Input LO [Btu/hr]
Maximum Output HI [Btu/hr]
Orifice Size (0-4500ft)
Air Shutter Opening
Gas Inlet Size
Gas Supply Pressure
Natural Gas [in. w.c.]
Propane [in. w.c.]
Manifold Pressure
High [in. w.c. / kPa]
Low [in. w.c. / kPa]

Gas Line Installation

MQHBZDV
4736N
4736LP
Natural
Propane
Millivolt Adjustable
40,000
36,000
27,000
30,000
27,200
24,100
#31
#49
5/16"
Fully Open
S.I.T. 820 Nova, 3/8" NPT
Minimum
Normal
Maximum
5.5"
7"
9"
11"
11"
12"
Nat. Gas
Propane
3.5" / 0.87 10" / 2.61
1.6" / 0.40 6.3" / 1.57
Important: Always check for gas leaks with
a soap and water solution. Do not use open
flame for leak testing.
4236N
4236LP
3636N
Natural
Propane
Natural
30,500
29,200
30,500
20,600
22,200
20,600
23,180
22,100
23,200
#36
#51
#36
3/16"
5/16"
3/16"
MQRB
3636LP
4236N
4236NT
Propane
Natural
Natural
29,200
30,500
24,000
22,200
20,600
18,000
21,900
23,180
-
#51
#36
#42
5/16"
1/16"
1/32"
4236LPT
Propane
24,000
19,000
-
#53
1/4"
34