Procedure 7.5 - Replacing The Column - Precor C842 Service Manual

Hide thumbs Also See for C842:
Table of Contents

Advertisement

Procedure 7.5 - Replacing the Column

1.
For C842, C846i and C846 version 2 units, skip to step 14. For C846 version 1 units,
continue with step 2.
2.
Set the on/off switch in the off position.
3.
Remove the left hand cover per Procedure 7.1.
4.
Remove the display housing per Procedure 7.12, steps 1-4.
5.
Disconnect the upper interconnect cable from the junction block located near the base of the
column (see Diagram 7.13).
Diagram 7.13 - Interconnect Cable Junction Blocks
Upper Interconnect Cable
6.
Remove the four bolts from the base of the column and remove the column.
7.
Carefully remove the upper interconnect cable from the column.
8.
Insert the upper interconnect cable into the replacement column. The interconnect cable
must protrude form the upper end of the column and the lower access hole.
C842, C842i, C846, C846i Upright and Recumbent Cycle
J
unction Block
Lower
Interconnect Cable