Outdoor unit location

It is now time to install the outdoor unit. The unit
should be placed where there is abundant
access to outdoor air. It must not be placed in a
shed, garage or similar location. There must be
at least 4 m of free space in front of the outdoor
unit, and at least 10 cm between the back of the
outdoor unit and the wall. You must also take
into account that water runs from the outdoor
unit during the defrosting process. Heating
cables in the bottom tray ensure that water
does not freeze in the unit. However, ice may
form on the ground where the drain runs out.

Outdoor unit mounts

The mounts must, if possible, be installed on a
brick wall. Suitable, stable attachment material
must be used if mounting the unit on a wooden
wall. A ground stand is recommended for
wooden walls. Mount the brackets with a centre
distance of 505 mm (not applicable to 416-086)
and at least half a metre above the ground. In
snowy areas, the distance to the ground should
be increased to ensure good air supply and
drainage.
ENGLISH

Outdoor unit installation

The outdoor unit is placed on the wall brackets with
vibration dampers under the unit's feet.
Do not tighten the nuts too hard so that the rubber is
compressed. This degrades the rubber's anti-vibration
properties.
To ensure adequate air flow, the distance between the
wall and outdoor unit must be min. 10 cm.
Note: Make sure the outdoor unit is horizontal. It is
very important that the outdoor unit is not tilted forward
or to the right too much. Adjust with additional shims
under the feet where necessary.