Mitsubishi Electric FR-A800 Installation Manuallines page 47

Hide thumbs Also See for FR-A800:
Table of Contents

Advertisement

Parameter Name
USB communication
548
check time interval
549
Protocol selection
NET mode operation
550
command source
selection
PU mode operation
551
command source
selection
Frequency jump
552
range
553
PID deviation limit
PID signal operation
554
selection
555
Current average time
Data output mask
556
time
Current average
value monitor signal
557
output reference
current
Second frequency
560
search gain
PTC thermistor
561
protection level
Energization time
563
carrying-over times
Operating time
564
carrying-over times
Second motor speed
569
control gain
Multiple rating
570
setting
Holding time at a
571
start
4mA input check
573
selection
Second motor online
574
auto tuning
Output interruption
575
detection time
Output interruption
576
detection level
Output interruption
577
release level
Traverse function
592
selection
Maximum amplitude
593
amount
Amplitude
compensation
594
amount during
deceleration
*2
For FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower
*3
For FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher
*14
The setting is available only with the 400V class.
*15
Differs according to model types (standard model, separated converter type, IP55 compatible model).
Initial
Setting Range
Value
0 to 999.8s,
9999
9999
0
0, 1
9999
0, 1, 9999
9999
1 to 3, 9999
9999
0 to 30Hz, 9999
9999
0 to 100%, 9999
0
0 to 3, 10 to 13
1s
0.1 to 1.0s
0s
0 to 20s
*2
0 to 500A
Rated
inverter
*3
0 to 3600A
current
0 to 32767,
9999
9999
Ω
0.5 to 30k
,
9999
9999
0
(0 to 65535)
0
(0 to 65535)
9999
0 to 200%, 9999
0 to 3/
0 to 3/
2
*15
1, 2
9999
0 to 10s, 9999
9999
1 to 4, 9999
0, 1
0
0 to 3600s,
1s
9999
0Hz
0 to 590Hz
1000%
900 to 1100%
0
0 to 2
10%
0 to 25%
10%
0 to 50%
Parameter Name
Amplitude
compensation
595
amount during
acceleration
Amplitude
596
acceleration time
Amplitude
597
deceleration time
*14
Undervoltage level
598
X10 terminal input
599
selection
First free thermal
600
reduction frequency 1
First free thermal
601
reduction ratio 1
First free thermal
602
reduction
frequency 2
First free thermal
603
reduction ratio 2
First free thermal
604
reduction frequency 3
Motor permissible
607
load level
Second motor
permissible load
608
level
PID set point/
609
deviation input
selection
PID measured value
610
input selection
Acceleration time at
611
a restart
Brake opening
639
current selection
Brake operation
640
frequency selection
Second brake
641
sequence operation
selection
Second brake
642
opening frequency
Second brake
643
opening current
Second brake
644
opening current
detection time
Second brake
645
operation time at
start
Second brake
646
operation frequency
DRIVE THE MOTOR
Initial
Setting Range
Value
10%
0 to 50%
5s
0.1 to 3600s
5s
0.1 to 3600s
350 to 430V,
9999
9999
*15
0, 1
0/1/0
0 to 590Hz,
9999
9999
100%
1 to 100%
0 to 590Hz,
9999
9999
100%
1 to 100%
0 to 590Hz,
9999
9999
150%
110 to 250%
110 to 250%,
9999
9999
2
1 to 5
3
1 to 5
0 to 3600s,
9999
9999
0
0, 1
0
0, 1
0
0, 7, 8, 9999
3Hz
0 to 30Hz
130%
0 to 400%
0.3s
0 to 2s
0.3s
0 to 5s
6Hz
0 to 30Hz
41