DRIVE THE MOTOR
Parameter Name
36
Frequency jump 3B
37
Speed display
Up-to-frequency
41
sensitivity
Output frequency
42
detection
Output frequency
43
detection for reverse
rotation
Second acceleration/
44
deceleration time
Second deceleration
45
time
46
Second torque boost
Second V/F
47
(base frequency)
Second stall
48
prevention operation
level
Second stall
49
prevention operation
frequency
Second output
50
frequency detection
Second electronic
51
thermal O/L relay
Operation panel main
52
monitor selection
FM/CA terminal
54
function selection
Frequency
55
monitoring reference
Current monitoring
56
reference
57
Restart coasting time
58
Restart cushion time
Remote function
59
selection
Energy saving
60
control selection
61
Reference current
Reference value at
62
acceleration
Reference value at
63
deceleration
*2
For FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower
*3
For FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher
*7
Differs according to the voltage class. (200V class/400V class)
*10
Differs according to types. (FM type/CA type)
*16
Setting available for standard models only.
34
Initial
Setting Range
Value
0 to 590Hz,
9999
9999
0, 1 to 9998
0
10%
0 to 100%
6Hz
0 to 590Hz
0 to 590Hz,
9999
9999
5s
0 to 3600s
0 to 3600s,
9999
9999
9999
0 to 30%, 9999
0 to 590Hz,
9999
9999
150%
0 to 400%
0 to 590Hz,
0Hz
9999
0 to 590Hz
30Hz
0 to 500A,
*2
9999
9999
0 to 3600A,
*3
9999
0, 5 to 14, 17 to
20, 22 to 35, 38,
40 to 45, 50 to
0
57, 61, 62, 64,
67, 87 to 98,
100
1 to 3, 5 to 14,
17, 18, 21, 24,
32 to 34, 50, 52,
1
*10
53, 61, 62, 67,
70, 87 to 90, 92,
93, 95, 97, 98
0 to 590Hz
60/50Hz
*2
Rated
0 to 500A
inverter
*3
0 to 3600A
current
0, 0.1 to 30s,
9999
9999
1s
0 to 60s
0 to 3, 11 to 13
0
0
0, 4, 9
0 to 500A,
*2
9999
9999
0 to 3600A,
*3
9999
9999
0 to 400%, 9999
9999
0 to 400%, 9999
Parameter Name
Starting frequency
64
for elevator mode
65
Retry selection
Stall prevention
66
operation reduction
starting frequency
Number of retries at
67
fault occurrence
68
Retry waiting time
Retry count display
69
erase
Special regenerative
16
70 *
brake duty
71
Applied motor
PWM frequency
72
selection
Analog input
73
selection
Input filter time
74
constant
Reset selection/
disconnected PU
75
detection/PU stop
selection
Fault code output
76
selection
Parameter write
77
selection
Reverse rotation
78
prevention selection
Operation mode
79
selection
Simple
Simple
Simple
*10
80
Motor capacity
Number of motor
81
poles
Motor excitation
82
current
83
Rated motor voltage
Rated motor
84
frequency
Initial
Setting Range
Value
9999
0 to 10Hz, 9999
0
0 to 5
*10
0 to 590Hz
60/50Hz
0 to 10,
0
101 to 110
1s
0.1 to 600s
0
0
0 to 100%
0%
0 to 6, 13 to 16,
20, 23, 24, 30,
33, 34, 40, 43,
44, 50, 53, 54,
0
70, 73, 74, 330,
333, 334, 8090,
8093, 8094,
9090, 9093,
9094
*2
0 to 15
2
*3
0 to 6, 25
1
0 to 7, 10 to 17
1
0 to 8
0 to 3,
*2
14 to 17
14
0 to 3, 14 to 17,
100 to 103,
*3
114 to 117
0
0 to 2
0
0 to 2
0
0 to 2
0
0 to 4, 6, 7
0.4 to 55kW,
*2
9999
9999
0 to 3600kW,
*3
9999
2, 4, 6, 8, 10,
9999
12, 9999
0 to 500A,
*2
9999
9999
0 to 3600A,
*3
9999
*7
0 to 1000V
200/400V
10 to 400Hz,
9999
9999