Mitsubishi Electric FR-A800 Installation Manuallines page 41

Hide thumbs Also See for FR-A800:
Table of Contents

Advertisement

Parameter Name
Speed control gain
89
(Advanced magnetic
flux vector)
90
Motor constant (R1)
91
Motor constant (R2)
Motor constant (L1)/
92
d-shaft inductance
(Ld)
Motor constant (L2)/
93
q-shaft inductance
(Lq)
94
Motor constant (X)
Online auto tuning
95
selection
Auto tuning setting/
96
status
100
V/F1 (first frequency)
V/F1 (first frequency
101
voltage)
V/F2
102
(second frequency)
V/F2 (second
103
frequency voltage)
V/F3
104
(third frequency)
V/F3 (third frequency
105
voltage)
V/F4
106
(fourth frequency)
V/F4 (fourth
107
frequency voltage)
108
V/F5 (fifth frequency)
V/F5 (fifth frequency
109
voltage)
Third acceleration/
110
deceleration time
Third deceleration
111
time
112
Third torque boost
Third V/F
113
(base frequency)
Third stall prevention
114
operation level
Third stall prevention
115
operation frequency
Third output
116
frequency detection
PU communication
117
station number
*2
For FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower
*3
For FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher
*10
Differs according to types. (FM type/CA type)
Initial
Setting Range
Value
9999
0 to 200%, 9999
0 to 50Ω,
*2
9999
9999
0 to 400mΩ,
*3
9999
to 50Ω,
*2
9999
9999
0 to 400mΩ,
*3
9999
0 to 6000mH,
*2
9999
9999
0 to 400mH,
*3
9999
0 to 6000mH,
*2
9999
9999
0 to 400mH,
*3
9999
9999
0 to 100%, 9999
0
0 to 2
0
0, 1, 11, 101
0 to 590Hz,
9999
9999
0V
0 to 1000V
0 to 590Hz,
9999
9999
0V
0 to 1000V
0 to 590Hz,
9999
9999
0V
0 to 1000V
0 to 590Hz,
9999
9999
0V
0 to 1000V
0 to 590Hz,
9999
9999
0 to 1000V
0V
0 to 3600s,
9999
9999
0 to 3600s,
9999
9999
9999
0 to 30%, 9999
0 to 590Hz,
9999
9999
150%
0 to 400%
0Hz
0 to 590Hz
*10
0 to 590Hz
60/50Hz
0
0 to 31
Parameter Name
PU communication
118
speed
PU communication
119
stop bit length /
data length
PU communication
120
parity check
Number of PU
121
communication
retries
PU communication
122
check time interval
PU communication
123
waiting time setting
PU communication
124
CR/LF selection
Terminal 2 frequency
setting gain
125
frequency
Simple
Simple
Simple
Terminal 4 frequency
setting gain
126
frequency
Simple
Simple
Simple
PID control
automatic
127
switchover
frequency
128
PID action selection
PID proportional
129
band
130
PID integral time
131
PID upper limit
132
PID lower limit
133
PID action set point
134
PID differential time
Electronic bypass
135
sequence selection
MC switchover
136
interlock time
137
Start waiting time
Bypass selection at a
138
fault
Automatic switch-
over frequency
139
between inverter and
commercial power-
supply operation
Backlash
140
acceleration
stopping frequency
DRIVE THE MOTOR
Initial
Setting Range
Value
48, 96, 192,
192
384, 576, 768,
1152
0, 1, 10, 11
1
2
0 to 2
1
0 to 10, 9999
0, 0.1 to 999.8s,
9999
9999
0 to 150ms,
9999
9999
0 to 2
1
0 to 590Hz
60/50Hz
0 to 590Hz
60/50Hz
0 to 590Hz,
9999
9999
0, 10, 11, 20, 21,
40 to 43, 50, 51,
60, 61, 70, 71,
80, 81, 90, 91,
0
100, 101, 1000,
1001, 1010,
1011, 2000,
2001, 2010,
2011
0.1 to 1000%,
100%
9999
0.1 to 3600s,
1s
9999
0 to 100%,
9999
9999
0 to 100%,
9999
9999
0 to 100%,
9999
9999
0.01 to 10.00s,
9999
9999
0
0, 1
0 to 100s
1s
0.5s
0 to 100s
0
0, 1
0 to 60Hz,
9999
9999
1Hz
0 to 590Hz
35
*10
*10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents