PRE-INSTALLATION
3.9

FLUE OPTIONS

ErP
The Greenstar CDi Classic
has the option of three horizontal RSF (60/
100 telescopic, 60/100 longer telescopic and 80/125 telescopic) flue
systems and two vertical RSF (60/100 or 80/125) regular flue systems:
The systems have different maximum flue lengths for different boiler
outputs and different plume management lengths.
For every extra 1000mm of plume management after the first 500mm,
the internal 60/100 flue length must be reduced by 700mm, up to a
maximum of 4500mm of plume management.
ErP
For example on a 29CDi Classic
length was 1500mm, the internal flue would be reduced to 5200mm.
Maximum horizontal flue lengths (L)
Boiler model 100mmØ
No Plume
+ 500mm
management
of plume
management
ErP
29CDi
7,900mm
5,900mm
ErP
34CDi
7,000mm
5,000mm
ErP
38CDi
6,000mm
4,000mm
ErP
42CDi
6,000mm
4,000mm
Table 10 Maximum horizontal flue lengths
Maximum vertical flue lengths (L)
Boiler model
100mmØ
ErP
29CDi
9,400mm
ErP
34CDi
8,000mm
ErP
38CDi
7,500mm
ErP
42CDi
7,500mm
Table 11 Maximum vertical flue lengths
This page and the next page show various flue options with the maximum
straight flue lengths allowed to remain within the maximum flue length.
NOTICE: 60/100 Flue systems:
▶ Each 90° bend used is equivalent to 1.5 metres of
straight flue.
▶ Each 45° bend used is equivalent to 0.75 metres of
straight flue.
NOTICE: 80/125 flue systems:
▶ Each 90° bend used is equivalent to 2.0 metres of
straight flue.
▶ Each 45° bend used is equivalent to 1.0 metre of
straight flue.
Telescopic horizontal flue
Flue option 1
100mmØ
ErP
29CDi
570mm
ErP
34CDi
570mm
ErP
38CDi
570mm
ErP
42CDi
570mm
Horizontal extended flue
Flue option 2
100mmØ
ErP
29CDi
7,900mm
ErP
34CDi
7,000mm
ErP
38CDi
6,000mm
ErP
42CDi
6,000mm
18
if the plume management effective
125mmØ
+4500mm
No plume
of plume
management
management
available
3,100mm
18,500mm
2,200mm
16,000mm
1,200mm
12,500mm
1,200mm
12,000mm
125mmØ
18,500mm
16,000mm
16,000mm
16,000mm
125mmØ
600mm
600mm
600mm
600mm
125mmØ
18,500mm
16,000mm
12,500mm
12,000mm
Horizontal extended flue with 1x90° bends
Flue option 3
100mmØ
ErP
29CDi
6,400mm
ErP
34CDi
5,500mm
ErP
38CDi
4,500mm
ErP
42CDi
4,500mm
Horizontal extended flue with 2x90° bends
Flue option 4
100mmØ
ErP
29CDi
4,900mm
ErP
34CDi
4,000mm
ErP
38CDi
3,000mm
ErP
42CDi
3,000mm
High level horizontal extended flue
Flue option 5
100mmØ
ErP
29CDi
7,900mm
ErP
34CDi
7,000mm
ErP
38CDi
6,000mm
ErP
42CDi
6,000mm
High level horiz. extended flue with 2x90° bends
Flue option 6
100mmØ
ErP
29CDi
6,400mm
ErP
34CDi
5,500mm
ErP
38CDi
4,500mm
ErP
42CDi
4,500mm
High level horiz. extended flue with 3x90° bends
Flue option 7
100mmØ
ErP
29CDi
4,900mm
ErP
34CDi
4,000mm
ErP
38CDi
3,000mm
ErP
42CDi
3,000mm
Vertical balanced extended flue
Flue option 8
100mmØ
ErP
29CDi
9,400mm
ErP
34CDi
8,000mm
ErP
38CDi
7,500mm
ErP
42CDi
7,500mm
Vertical balanced extended flue with 2x90° bends
Flue option 9
100mmØ
ErP
29CDi
6,400mm
ErP
34CDi
5,000mm
ErP
38CDi
4,500mm
ErP
42CDi
4,500mm
Vertical balanced extended flue with 2x45° bends
Flue option 10
100mmØ
ErP
29CDi
7,900mm
ErP
34CDi
6,500mm
ErP
38CDi
6,000mm
ErP
42CDi
6,000mm
125mmØ
16,500mm
14,000mm
10,500mm
10,000mm
125mmØ
14,500mm
12,000mm
8,500mm
8,000mm
125mmØ
18,500mm
16,000mm
12,500mm
12,000mm
125mmØ
16,500mm
14,000mm
10,500mm
10,000mm
125mmØ
14,500mm
12,000mm
8,500mm
8,000mm
125mmØ
18,500mm
16,000mm
16,000mm
16,000mm
125mmØ
14,500mm
12,000mm
12,000mm
12,000mm
125mmØ
16,500mm
14,000mm
14,000mm
14,000mm
6 720 815 725 (2015/05)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

34cdi classic42cdi classic38cdi classic

Table of Contents