Floor standing oil fired condensing boiler conventional flue & room sealed flue for fully pumped open vent or sealed central heating systems and domestic hot water cylinders (20 pages)
Summary of Contents for Worcester Greenstar Danesmoor 25kW
Page 1
GREENSTAR DANESMOOR 18-25kW GB/IE USER INSTRUCTIONS & CUSTOMER CARE GUIDE...
Page 2
WORCESTER BOSCH: PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE OPERATING YOUR APPLIANCE. Service call centres: Other enquiries: ANY DOUBT DO NOT INTERFERE WITH ANY SEALED WATER TREATMENT: COMPONENTS. FLUE TERMINAL GUARDS: ABBREVIATIONS: OIL FIRING TECHNICAL ASSOCIATION:...
OIL SMELLS, LEAKS OR FUMES FROM THE FITTING & MODIFICATIONS: APPLIANCE: HEALTH & SAFETY: SERVICING: COMBUSTIBLE AND CORROSIVE MATERIALS: DO NOT OPERATE THE APPLIANCE WHEN:...
BOILER LOCATION: THIS BOILER IS NOT SUITABLE FOR ROOF SPACE INSTALLATION. VENTILATION: * If this clearance is less than 75mm the flue 'knock- out' panel sections must be removed to improve air circulation and cooling. Conventional flued appliances:...
Page 8
Venting compartments: MINIMUM AIR VENT AREA (cm²) FOR APPLIANCES INSTALLED IN A COMPARTMENT: *Internal air to and from a space/room inside the building. **External air to and from directly outside the building. Conventional flue: Room Sealed flue:...
Page 9
(see instructions supplied with programmer for details) (behind front panel) TIMED TIMED ONCE ONCE HOT WATER CENTRAL HEATING (behind ADVANCE SET ? ADVANCE SELECT SELECT front panel) (behind front panel)
SWITCHING THE BOILER ON/OFF: TEMPERATURE CONTROL: If the appliance is left unused and exposed to freezing conditions; shut off all the mains supplies, isolate the boiler and drain the system and boiler. SETTING TEMPERATURE: The 'Demand' light will illuminate until the water reaches the set temperature on the heating control.
FAULT CONDITIONS: Normal operation: a) Demand light: Demand and Lockout lights: b) Both lights ON, boiler not firing; Both lights OFF, boiler not on, no heating/hot water; ACCESSING RESET BUTTONS:...
Page 13
Heating economically: Roof insulation: Window frames: Curtains: Draughts: Warning: do not block or seal any air vents that are installed to ensure the central heating boiler (or other appliance) operate safely.
Page 14
Room thermostats: New control systems: Radiators:...
USER INSTRUCTIONS & CUSTOMER CARE GUIDE www.worcester-bosch.co.uk Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR4 9SW Worcester, Bosch Group is a trading name of BBT Thermotechnology UK Ltd.