Prime Menu; Volt Select - Kohler 6EKOD Operation Manual

Marine generator sets
Hide thumbs Also See for 6EKOD:
Table of Contents

Advertisement

2.10.10 Prime Menu

This menu, if confirmed, allows the user to initiate the
electric fuel pump to prime the fuel system.
Prime the Fuel System
Push To Prime ---->

2.10.11 Volt Select

This menu allows the user to readily change controller
voltage settings.
Note: The generator set output leads require voltage
reconnection. See the installation manual for
voltage reconnection information.
With the generator set stopped, go to the Volt Select
menu.
Then push and hold the pushbutton/rotary
selector dial until the voltage selection starts to flash.
Volt selection is now available. Scroll to the desired
voltage and momentarily press the pushbutton/rotary
selector dial to confirm the voltage selection.
40
Section 2 Operation
Confirm
Prime? Yes
OR
Confirm?
Prime? No
Volt Select
Volt Select: ---->
###/### V # Ph
120/240 V 1 Ph
120/208 V 3 Ph
139/240 V 3 Ph
277/480 V 3 Ph
120/240 V 3 Ph
115/230 V 1 Ph
120 V 1 Ph
230 V 1 Ph
240 V 1 Ph
110/190 V 3 Ph
127/220 V 3 Ph
115/230 V 3 Ph
230/400 V 3 Ph
240/416 V 3 Ph