Recommended Heights For Woodstove Flue - HAMPTON BAY H300 Owners & Installation Manual

Freestanding
Table of Contents

Advertisement

Simple rules on draft. See Table 1.
1) At sea level minimum height is 12'
straight.
2) Add the following vertical height to compen-
sate for:
45 deg. elbow
= 1 ft.
90 deg. elbow
= 2 ft.
"T"
= 3 ft.
Each foot of horizontal run = 2 ft.
3) Add 4% overall for each 1000' above sea
level.
ELEVATION (FT)
ABOVE SEA LEVEL
9000-10000
NOTE: No more than two offsets (four elbows) allowed. Two 45
Hampton H300 Cast Freestanding Woodstove
RECOMMENDED HEIGHTS FOR
WOODSTOVE FLUE
Example: a)
1-1/2 ft. of horizontal run
one "T"
Total Addition (at sea level)
Example: b)
One 90 deg. elbow
2 ft. of horizontal run
one "T"
Total Addition (at sea level)
MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET
0-1000
1000-2000
2000-3000
3000-4000
4000-5000
5000-6000
6000-7000
7000-8000
8000-9000
= 3 ft.
= 3 ft.
= 6 ft.
= 2 ft.
= 4 ft.
= 3 ft.
= 9 ft.
TABLE 1
(Measured from the top of the unit)
# OF ELBOWS
0
2 x 15
4 x 15
o
o
12.0
13.0
14.0
12.5
13.5
14.5
13.0
14.0
15.0
13.5
14.5
15.5
14.0
15.0
16.0
14.5
15.5
17.0
15.0
16.0
17.5
15.5
16.5
18.0
16.0
17.0
18.5
16.5
17.5
19.0
elbows equal one 90
o
INSTALLATION
Recommended Flue Height
Elevation
Example a)
0'
18'
1000'
18.72'
2000'
19.44'
5000'
21.60'
8000'
23.76'
2 x 30
4 x 30
2 x 45
o
o
o
15.0
18.0
16.0
15.5
19.0
16.5
16.0
19.5
17.0
17.0
20.0
18.0
17.5
21.0
18.5
18.0
21.5
19.0
18.5
22.5
20.0
19.0
23.0
20.5
20.0
24.0
21.0
20.5
24.5
22.0
elbow.
o
Example b)
21'
21.84'
22.68'
25.20'
27.72'
4 x 45
o
20.0
21.0
21.5
22.5
23.0
24.0
25.0
25.5
26.5
27.0
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents