A combustible floor must be protected by non-combustible material (like tile, concrete board, or certified to UL-1618 or as defined by local codes)
extending beneath the heater and a minimum of 6" from each side and minimum 18" from the front face of the stove and minimum 6" (or the rear
clearance to combustibles whichever is smaller) from the rear of the stove.
When installed with horizontal venting, non-combustible floor protection must beneath the flue pipe and extend 2" (51mm) beyond each side.
A minimum of a 3/8" thick thermal floor protector with a 0.84k factor is required when installing the standard or optional short legs. This applies to
both Canada and the US. All other requirements (ie. hearth size) remain the same.
IF SIDE LOAD DOOR IS USED:
Floor protection must extend 18" (457mm)
from the side of the unit to the wall.
Minimum Overall Depth (Y) of Floor Protector
Unit
H300 (US)
H300 (Canada)
Minimum Overall Width (X) of Floor Protector for all installations:
H300
Hampton H300 Cast Freestanding Woodstove

FLOOR PROTECTION

Residential
"C" Vent
Y
Z
44-1/2"
6" (152 mm)
(1130 mm)
46-1/2"
8" (203 mm)
(1181 mm)
39" (990 mm) - US
43" (1092mm) - Canada
NOTE: In Canada, floor protection must
Residential
Mobile Home
Close Clearance
Close Clearance
Y
Z
44-1/2"
6" (152 mm)
(1130 mm)
(1130 mm)
46-1/2"
8" (203 mm)
(1181 mm)
(1181 mm)
INSTALLATION
extend 18" (450mm) to the front
and 8" (200mm) to each side and
back of the stove.
Alcove
Y
Z
Y
44-1/2"
6" (152 mm)
44-1/2"
(1130 mm)
46-1/2"
8" (203 mm)
46-1/2"
(1181 mm)
Z
6" (152 mm)
8" (203 mm)
11