The diagnostic plotter displays all of the data from the cascaded Histograms 1, 2 and 3. It
uses a bespoke x-axis with a compressed timeline so that resolution is not sacrificed. The
most recent data is shown to the right, and the oldest data to the left.
The most recent hour's worth of data from Histogram 1 is displayed between 0 minutes (0m)
and 60 minutes (60m) to the right of the x-axis;
Histogram 2 is displayed between 60 minutes (60m) and 25 hours (25h) in the middle of the
x-axis; Data for the previous 30 days from Histogram 3 is displayed between 25 hours (25h)
and 31 days (31d) to the left of the x-axis.
The Trace selection allows the user to control which traces are plotted.
As with other management pages the page refresh period can be used to interactively
monitor the wireless link.

8.3.16 Diagnostic Download

The diagnostics Download page allows the system administrator to download snapshots of
system diagnostics.
The following diagnostics are available:
Vector Error
Rx Power
Tx Power
Signal Strength Ratio V/H
Link Loss
Rx Data Rate
Tx Data Rate
Aggregate Data Rate
Receive SNR
Rx Gain