Figure 53 - Software Upgrade Image Check

The user should ensure that the correct image is shown before pressing the "Program
Software Image into Non-Volatile Memory" button. Once this button has been pressed the
image is stored into non-volatile memory. This process can take up to 60 seconds and must
not be interrupted. A progress tracking web page will be presented to the user during the
erasure and programming of non-volatile memory.
WARNING: If the upgrade process is interrupted during the erasure of the image bank or
during the reprogramming of the image bank the image bank will be left in a corrupt state. If
this occurs the software must be reloaded. On power up, if the software image is invalid, for
any reason, the PTP 400 Series bridge will use a known good fixed image. If this occurs the
user must attempt to reload the correct version of software.

Figure 54 - Overall Progress Tracker