Power Indoor Unit LED check chart:
Mode
No Power Applied
Power Applied
Valid Ethernet Link and
no traffic
Valid Ethernet Link with
traffic
While Recovery Switch
Pressed
Recovery Switch Pressed
and released within 10
seconds during normal
operation
Recovery Switch Pressed
and held for > 20
seconds during normal
operation
Recovery Switch Pressed
and held for >40 seconds
from power on (Recovery
is pressed while power is
applied)
27
It is possible that some units may have been previously configured with IP addresses 10.10.10.10
(Slave) and 10.10.10.11 (Master). Therefore the IP address will be reset to 10.10.10.10/11.
Yellow LED No
Green
Ethernet Cable
LED
Connected
Off
Off
Will flash once per
second regularly
approximately 16
On
seconds after power
applied for 10
seconds then will go
out and stay out
On
N/A
On
N/A
On
Off
On
Off
Off while switch pressed.
One second after release, flashes twice per second
regularly for 10 seconds, then erases non-volatile
configuration data and resets. The erasure will reset all the
On
unit's configuration apart from the last known wireless link
configuration. This ensures that after a reset the wireless
link SHOULD re-establish without any user intervention.
The IP address will be reset to 169.254.1.1
Off while switch pressed.
One second after release, flashes regularly twice per
second for 10 seconds. Then erases non-volatile
configuration data & the downloaded image and resets.
The erasure will reset all the unit's configuration apart from
On
the last known wireless link configuration. This ensures that
after a reset the wireless link SHOULD re-establish without
any user intervention.
The IP address will be reset to 169.254.1.1 and the unit will
boot the fixed software image.
139
Yellow LED Ethernet Cable
Connected between PIDU Plus and
NIC/Switch/Hub
Off
Will flash regularly once per second
approximately 16 seconds after
power applied for 10 seconds then
operate as Ethernet Link/Activity
LED
Will be on solid for a valid link.
Will be on solid, but will blink
randomly as traffic passes through
Off
Off while switch pressed but returns
to LINK/Activity state when
released. No reset will take place
27