Should it be necessary to disconnect the PIDU Plus to ODU cable at the ODU this can be
achieved by removing the weather proofing gland and depressing the RJ45 locking tab with a
small screwdriver as shown below:
Warning: Ensure that power is removed from the system at the PIDU Plus to prevent damage
to the ODU while making or breaking the connection.
7.7.3

Routing the Cable

After connecting the cable to the ODU it can be routed and secured using standard cable
routing and securing techniques. When the cable is in place it can then be cut to the desired
length at the PIDU Plus prior to connection to the PIDU Plus.
7.7.4

Fitting A Surge Arrestor

If you have opted to fit a Surge Arrestor, this should be installed by following the
manufacturer's instructions. For recommended types see Section 11 "Lightning Protection"

Figure 21 - Disconnecting the ODU