C
Specifications
Chassis
Height
Width
Depth
Approximate Weight
Temperature Range
Operating
Nonoperating
NOTE:
Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct
sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options
installed.
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
Maximum Altitude (unpressurized)
Operating
Nonoperating
Power Supply
Standard Efficiency
High Efficiency
80 PLUS Bronze
Rated Voltage Range
Rated Line Frequency
Operating Line Frequency
Rated Input Current
Rated Input Current with Energy Efficient Power Supply
Current Leakage (NFPA 99)

136 Appendix C Specifications

1
13.98 in
6.50 in
14.10 in
14.33 lb
50° to 95°F
-22° to 140°F
10-90%
5-95%
10,000 ft
30,000 ft
300W & 180W active PFC (230 VAC input only)
180W Reg (115V/230 VAC input only)
180W active PFC EStar 6
82/85/82% efficient at 20/50/100% load (115V)
82/85/82% efficient at 20/50/100% load (230V)
200 - 240 VAC (300W & 180W active PFC)
100 - 240 VAC (180W ENERGY STAR® 6)
115 VAC/230 VAC (180W Reg)
50-60 Hz
47-63 Hz
4A/200 VAC, 8A/100 VAC
6.3A/100 VAC
2
<900uA / 230 VAC
355 mm
165 mm
358 mm
6.50 kg
10° to 35°C
-30° to 60°C
10-90%
5-95%
3048 m
9144 m