Fireplace Placement Requirements; Minimum Framing Dimensions - FireplaceXtrordinair 44 DV XXL Owner's Manual

Hide thumbs Also See for 44 DV XXL:
Table of Contents

Advertisement

Installation

Fireplace Placement Requirements

Minimum Framing Dimensions

The 1Ó stand-offs along the front corners, the 1Ó clearance requirement around the sides and back,
and the 10-1/2" stand-offs on the top of the fireplace separate the fireplace from combustible
materials (e.g.: combustible framing members, plywood, sheetrock, paper-backed insulation). The
stand-offs may contact the framing members but no material may be placed between the stand-offs or
into the required 1Ó clearance to the sides and back
5-1/2" Clearance Min.
(before firestop)
The fireplace enclosure
must not be less than
75" above the base of
the fireplace.
If using a remote
control or thermostat,
route the wire to a
location near the gas
line (include an extra 3'
length for hookup).
Gas line (3/8" M.P.T. or 1/2"
F.P.T.) should be routed 6-12"
behind the framing opening
and 2-3/8" above the base of
the fireplace (see "Gas Line
Connection" for details).
Fireplace must be installed on a level surface capable of supporting the fireplace and vent
Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet)
Due to the high temperature of the fireplace, it should be located out of traffic and away from furniture
and draperies.
Travis Industries
Required Firestop (included with
the fireplace)
75" Min.
50-3/4"
24-3/8"
52"
(for qualified installers only)
3" Clearance Min. (after firestop)
9 3 5 0 8 1 0 9
NOTE: if venting directly to the rear,
make sure there is a min. 12" space
centered behind the fireplace.
1" Clearance min. to the sides
and below the vent (before or
after firestop).
Minimum 65-1/2" above the
base of the fireplace (includes
18" min. rise before elbow -
see the section "Horizontal
Termination Requirements")
Route the electrical line to a position
at the right rear of the fireplace.
NOTE: If using the power heat vent,
allow for the duct passage when
framing the enclosure.
1 8 0 5 0 1
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents