Optional Equipment
3
Follow the directions below to remove the natural gas orifices. Apply thread sealant to the LP orifices
and tighten them in place with a 1/2" open end wrench (make sure to install the orifices correctly Ð see
the illustration below). Slide the adjustable shutter back in place over the orifice.
a
Loosen the air shutter control and move
it all the way to the left (see page 34).
This will allow for the main (lower) orifice
to be removed.
Air
Shutter
Apply thread sealant to the LP orifices prior
to installation. Use the chart below to
identify the correct orifices.
Look here for the orifice identification
Front (upper)
Main (lower)
4
Remove the pilot shield following the directions below.
Travis Industries
c
LP
NG
#64
.0625
#45
#29
9 3 5 0 8 1 0 9
(for qualified installers only)
b
Use a 1/2Ó open end wrench
to unscrew both orifices.
View from the Rear
Front Burner Orifice
Main Burner Orifice
d
Screw the LP orifice in so the orifice shoulder
protrudes 5/16Ó (indicating full insertion).
5/16Ó
5/16Ó
Pilot Shield
4 7