  • Page 1 Supreme Resolution WDR Camera User Manual SCB-5005...
  • Page 2: User Manual

    Samsung Techwin. Disclaimer Samsung Techwin makes the best to verify the integrity and correctness of the contents in this document, but no formal guarantee shall be provided. Use of this document and the subsequent results shall be entirely on the user’s own responsibility.
  • Page 3 Before operating the camera, confirm the camera model and correct input power voltage. To help you understand this manual thoroughly, we'll introduce our model description. ■ SCB-5005 SERIES • NTSC MODEL • PAL MODEL SCB-5005N SCB-5005P ■ MODEL DESCRIPTION • SCB-5005X SIGNAL SYSTEM • SIGNAL SYSTEM...
  • Page 4 safety information CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit.
  • Page 5 If this product fails to operate normally, contact the nearest service center. never disassemble or modify this product in any way. (samsung is not liable for problems caused by unauthorized modifications or attempted repair.) When cleaning, do not spray water directly onto parts of the product.
  • Page 6: Fcc Statement

    safety information fCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions : This device may not cause harmful interference, and This device must accept any interference received including interference that may cause undesired operation.
  • Page 7: Important Safety Instructions

    Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus Samsung Techwin cares for the environment at all product manufacturing stages to preserve the environment, and is taking a number of steps to provide customers with more environment-friendly products.The Eco mark represents...
  • Page 8: Table Of Contents

    contents inTroDuCTion Features Components and Accessories Overview Lens ConnECTion Connecting to Monitor Connecting to Power Control via RS-485 Interface Using Coaxial Communications CamEra oPEraTion Menu Configuration Menu Setup TroublEshooTing Troubleshooting sPECifiCaTions Specifications Dimension _ contents...
  • Page 9: Introduction

    Without an external sensor, you can use this product to detect motion and generate alarms and thus more efficient monitoring can be achieved. ssnr4 (samsung super noise reduction) function  High performance W7 Chip removes noises of GAIN resulting from the low light level and shows a vivid, high definition video even in the dark place.
  • Page 10: Components And Accessories

    Communication  Coaxial and RS-485 communication methods are supported. - Coaxial Communications : Pelco Coaxitron - RS-485 Communications : Samsung-T, Samsung-E, PELCO-D, PELCO-P, BOSCH, HONEYWELL, VICON, PANASONIC, GE, AD  The camera’s OSD is complimented by 17 languages. - English, Japanese, Spanish, French, Portuguese, Korean, German, Italian, Chinese, Russian, Polish, Czech, Romanian, Serbian, Swedish, Danish, Turkish.
  • Page 11: Overview

    ovErviEW front view Tripod mounting bracket screw hole : ❶ Used to fix the camera on a bracket. The screw sizes for this hole are as follows. 1/4"-20 UNC (20 THREAD) L:4.5mm±0.2mm (ISO standard), or 0.197" (ASA standard) lens adaptor : IInstall this if you use the lens. auto iris lens Connector : Used to connect Auto Iris Lens plug.
  • Page 12: Rear View

    introduction rear view ❿ ⓫ function setup button ❶ SET button : (Long press) The SIMPLE FOCUS operates.  (Short press) The menu screen is displayed. Use it to go the lower menu on the menu screen. Up & Down button : Used to move the cursor up or down in the menu screen. ...
  • Page 13 D & n input Port : You can switch to Day & Night Mode by connecting an external ❺ signal to this port. mD output Port : Motion detection signals are output through this port. ❻ ❼ video ouT Terminal : Sends video signal and connects to the video input terminal of the monitor. ❽...
  • Page 14: Lens

    introduction lEns The lens is not supplied with this camera. Purchase a lens suitable for your environment. This camera accepts the auto iris lens and both C-and CS-mount lens. To get the best performance from this product, use a mega pixel DC / P-Iris type automatic iris lens. Keep the lens surface clean, if it becomes contaminated with dirt or fingerprints the picture quality suffers.
  • Page 15 Use the lens connector shown in the following figure. If the dimensions of the connector are not correct, it may damage the camera, or the lens may not be installed firmly. If the lens is too heavy, the camera becomes unbalanced and there may be problems.
  • Page 16: Connection

    ConnECTing To moniTor Connect the Video OUT port on the rear panel of the camera to a monitor. Monitor SCB-5005 As the connecting method varies with the instruments, refer to the manual supplied  with the instrument. Only connect the cable when the power is turned off.
  • Page 17: Control Via Rs-485 Interface

    * RS-485 Communication establishment initial value Item Camera ID BAUD RATE UART MODE RET PKT Initial value 9600 8-NONE-1 ENABLE To control the camera by constructing an additional controller, use the SAMSUNG-T, SAMSUNG-E, PELCO-D, PELCO-P, BOSCH, HONEYWELL, VICON and PANASONIC, GE, AD protocol. English_1...
  • Page 18: Using Coaxial Communications

    connection using Coaxial CommuniCaTions Coaxial Communications System  OSD Control method  CAMERA CONTROLLER MENU/ENTER OSD KEY UP KEY JOYSTICK UP DOWN DOWN KEY JOYSTICK DOWN LEFT LEFT KEY JOYSTICK LEFT RIGHT RIGHT KEY JOYSTICK RIGHT ALARM NETWORK BACKUP ZOOM FREEZE BACKUP SEARCH...
  • Page 19: Menu Setup

    camera operation mEnu ConfiguraTion main sETuP BASIC DAY/NIGHT BACKLIGHT ● ● ● PROFILE INDOOR USER ● ● ● SSDR ● ● OUTDOOR INDOOR ● ● ● WHITE BAL ● AWC  SET MANUAL MERCURY ● ● ● BRIGHTNESS ● LENS ●...
  • Page 20 camera operation MAIN SETUP ▶ 1. PROFILE BASIC Select the function Change the status using the UP or 2. SSDR using the LEFT or DOWN button. RIGHT button. 3. WHITE BAL 4. EXPOSURE 5. BACKLIGHT 6. SIMPLE FOCUS 7. SPECIAL 8.
  • Page 21 If you select the traffic monitoring mode, the shutter will be set to 1/200 sec. Noise can be detected at night. ssDr (samsung super Dynamic range) If an object has a large variance between bright and dark areas, it will keep bright areas bright and make selected dark areas bright, so that the overall brightness can be maintained.
  • Page 22 camera operation White bal (White balance) Use the White Balance function to adjust the screen color. When the SETUP menu screen is MAIN SETUP displayed, select ‘White Bal’ by 1. PROFILE BASIC using the Up and Down buttons so 2. SSDR that the arrow indicates ‘White Bal’...
  • Page 23 ExPosurE When the SETUP menu screen is displayed, select ‘EXPOSURE’ by using the Up and Down buttons so that the arrow indicates ‘EXPOSURE’. Press the SET button. EXPOSURE SETUP Select a desired mode using the 4 ▶ BRIGHTNESS ---- ---- ...
  • Page 24 camera operation SHUTTER 1 SHUTTER 2 SHUTTER 3 1/60(1/50) 1/120(1/100) 1/250 1/500 1/700 1/1000 1/1600 1/2500 [Interlace Mode] The greater the shutter value the brighter the screen is but the more the residual images of objects there are. If the min shutter value is large, it can cause noise, spots and white areas but still operate normally. If you do not use the AGC mode on the exposure menu, it cannot be set above 1/60sec.
  • Page 25 baCKlighT The camera uses our own W7 chips that are designed to clearly display the object and the background despite severe reverse light. When the SETUP menu screen is displayed, select ‘BACKLIGHT’ by using the Up and Down buttons. so that the arrow indicates ‘BACKLIGHT’. Select a desired mode using the Left and Right buttons depending on the camera purpose.
  • Page 26 camera operation WDr : When there are both bright and dark areas at the same time, this mode makes  both areas distinctive. LEVEL : Select one from low, WDR SETUP med, high to adjust the LEVEL MIDDLE ▶ 1. brightness of the WDR RETURN setup.
  • Page 27 simPlE foCus When the SETUP menu screen is displayed, select ‘SIMPLE FOCUS’ by using the Up and Down buttons so that the arrow indicates ‘SIMPLE FOCUS’. Press the SET button. SIMPLE FOCUS Select a desired mode using the 4 ▶ SIMPLE FOCUS direction buttons.
  • Page 28 camera operation sPECial When the SETUP menu screen is displayed, select ‘SPECIAL’ by using the Up and Down buttons so that the arrow indicates ‘SPECIAL’. Press the SET button. SPECIAL SETUP Select a desired mode using the 4 DISPLAY ▶ 1. direction buttons.
  • Page 29 6. COAX PROTOCOL. RETURN (SAMSUNG-T, SAMSUNG-E, PELCO-D, PELCO-P, BOSCH, HONEYWELL, VICON, PANASONIC, GE and AD) CAM ID : Determines the camera's identification number (between 0 and 255). BAUD RATE : You can select 2400/4800/9600/19200/38400/57600 bps . UART MODE : You can select NONE, EVEN or ODD for the parity bits.
  • Page 30 camera operation PED LEVEL : The setting range is 1 ~ 100. The closer to 100 the setting is, the higher the PED level gets. COLOR GAIN : The setting range is 1 ~ 100. The smaller the setting value is the smaller the color gain gets and the more color blind it gets.
  • Page 31 DURATION : This function is used to select the brightness of light where  switching occurs. GAIN LEVEL HIGH Color→B/W B/W→Color Color→B/W B/W→Color Color→B/W B/W→Color VERY SLOW SLOW NORMAL FAST VERY FAST ※ Depending on the installation environment and the exposure menu’s gain mode setting, the switching brightness may vary.
  • Page 32: Video Analytics

    camera operation If the defog mode is set to Auto, and if the amount of fog is reduced, the function level will be also reduced. If you want to maintain the same level of defogging, set it to Manual. If there is little fog and the manual fog level is high, the screen contrast can get high. PrivaCY : Mask an area you want to ...
  • Page 33 SENSITIVITY : Set the sensitivity to tampering detection.  ALARM OUT : Outputting of detection signals can be set.  EXTERNAL : Send signals through external terminals. OSD : Display signals on the screen. RETURN : Return to the TAMPERING menu. RETURN : Return to the VIDEO ANALYTICS menu.
  • Page 34 camera operation NON DET. AREA : Specify a detection exception area to mask.Select a  mask area number and specify the size and position. SEL AREA : You can select up to 4 areas. MODE : Determines whether to use the area selected in the AREA. TOP/BOTTOM/LEFT/RIGHT : Adjust the size and position of the selected area.
  • Page 35 1) LINE FENCE SEL POS : Selects a LINE FENCE position from SEL POS ▶ POS1 POS1,POS2. X POS ---- ----  X POS / Y POS : Y POS --------  Adjust the size and position DIRECTION RIGHT of the selected line fence. RETURN DIRECTION RIGHT : Detects objects moving left to right on the fence line.
  • Page 36 camera operation ALARM OUT : When object movement is detected, the detection signal will  be outputted. EXTERNAL : Send signals through external terminals. OSD : Display signals on the screen. RETURN : Return to the INTELLIGENCE menu. RETURN : Return to the VIDEO ANALYTICS menu. ...
  • Page 37 ExiT Select a desired EXIT mode using the Function Setup switch depending on the camera purpose. savE : Save the current settings and exit the MAIN SETUP menu.  noT savE : Do not save the current settings and exit the MAIN SETUP menu. ...
  • Page 38 troubleshooting Troubleshooting If you have trouble operating your camera, refer to the following table. If the guidelines do not enable you to solve the problem, contact an authorized technician. Problems Troubleshooting Nothing appears on the screen. Check that the power cord and line connection between the ...
  • Page 39 specifications sPECifiCaTions sCb-5005n sCb-5005P Video Imaging Device 1/3” 1.3M CMOS 1312(H) x 1069(V) Total Pixels 1305(H) x 1049(V) Effective Pixels Progressive Scan Scanning System Internal Synchronization Frequency H : 15.734KHz / V : 59.94Hz H : 15.625KHz / V : 50Hz Color : 1000 TVL Horizontal Resolution B/W : 1000 TVL...
  • Page 40 1 Out Alarm Coaxial Control ( SPC-300 Compatible ), RS-485 Communication Coax : Pelco-C (Coaxitron) Protocol RS-485: Samsung-T, Samsung-E, Pelco-D, Pelco-P, Panasonic, Bosch, Honeywell, Vicon, AD, GE Environmental Operating Temperature -10°C ~ +55°C / Less than 90% RH / Humidity Electrical Dual ( 24VAC±10% &...
  • Page 41: Dimension

    DimEnsion Unit: mm English_1...
  • Page 42 MEMO...
  • Page 43 SALES NETWORK SAMSUNG TECHWIN CO., LTD. 6, Pangyo-ro 319beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do, SEOUL 463-400 Rep. of KOREA Tel : +82-70-7147-8753, 8764 Fax : +82-31-8018-3740 www.samsungsecurity.com SAMSUNG TECHWIN AMERICA Inc. SAMSUNG TECHWIN EUROPE LTD. 100 Challenger Rd. Suite 700 Ridgefield Park, NJ 07660 2nd Floor, No.

Table of Contents