wsm RTV900 Workshop Manual page 448

Hide thumbs Also See for RTV900:
Table of Contents

Advertisement

RTV900-TS, WSM
(2) Hydraulic Oil Cooling System
Fan Motor WIring Harness
1. Disconnect the wiring lead (1) from oil temperature switch after
turning the main switch OFF.
2. Turn the main switch ON and connect terminal A connect to
terminal B with a jumper lead (4).
3. If the oil cooler fan motor does not rotate wiring harness or relay
is faulty
(1) Wiring Harness
(2) Oil Temperature Sensor
(3) Connector
(4) Jumper Lead
Oil Temperature Switch
1. Measure the resistance with an ohmmeter across the switch
terminal and the switch body.
2. If 0 ohm is not indicated in the oil temperature at 55 °C (131 °F)
or more, the sensor is faulty.
3. If infinity is not indicated in the oil temperature at lower than 53
°C (127 °F), the sensor is faulty.
At oil temperature
lower than 53 °C
Resistance
(127 °F)
(Switch terminal –
At oil temperature
Switch body)
more than 55 to 65 °C
(131 to 149 °F)
(1) Oil Temperature Sensor
H8-S2
ELECTRICAL SYSTEM
(a) From Fan Motor Relay
W1018763
Infinity
0 Ω
(2) Oil
W1018994
KiSC issued 03, 2008 A