DIRECTIVE DECLARATION OF CONFORMITY Esab Welding Equipment AB, 695 81 Laxå, Sweden, declares that cooling unit OCF 2 from serial number 803 onwards, conforms to standard EN 60204--1, in accord- ance with the requirements of directive (73/23/EEC) and appendix (93/68/EEC) and standard EN 50199 in accordance with the requirements of directive (89/336/EEC) and appendix (93/68/EEC).
500x290x190 470x260x190 470x260x190 *) OCF 2D is a special version with larger external dimensions, but otherwise the same as OCF 2L. Enclosure class The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid objects or water.
This product is intended for industrial use. In a domestic environment this product may cause radio interference. It is the user’s responsibility to take adequate precautions. OCF 2L/OCF 2D To be installed by an electrician. OCF 2M/OCF 2A May be installed by user.
Page 7
5.1.1 Connection OCF 2L to LTN/LTR 200,255, NOT FITTED with connecting cable for cooling unit. 1. Unplug if necessary. 2. Remove the lower screws from the sides of the power source. 3. Remove the rear panel from the power source.
Page 8
OCF 2L to LTN/LTR 200,255, and OCF 2D to DTE. FITTED with connecting cable for cooling unit. 1. Unplug if necessary. 2. Remove the lower screws from the sides of the power source. 3. Remove the rear panel from the power source.
Page 9
OCF 2A to LTN/LTR 160. 1. Remove the lower cross--head screws from the sides of the power source. 2. Place the power source on the cooling unit. 3. Tighten the screws in the bottom through the cover on the cooling unit. 4.
OPERATION Glycol The cooling unit contains poisonous glycol which must not be drunk or poured down the drain or into the soil or water. Regularly top up the tank to a level 1 cm below the top if water is lost during hose changes. Avoid using glycol if the conditions are not cold enough to warrant it.
Replace the coolant about once a year. Refill with glycol mixture if the cooling unit is to be used or stored in freezing conditions. TROUBLESHOOTING In case of major faults, contact your nearest ESAB authorised service workshop or dealer. Fault...