Modifying And Scanning Time Programs; General Notes - Viessmann Vitotronic 200 KW2 Operating Instructions Manual

Heating system with weather-compensated digital boiler and heating circuit control
Hide thumbs Also See for Vitotronic 200 KW2:
Table of Contents

Advertisement

General notes

You can set time programs for central heating, for DHW heating (subject to a
DHW cylinder being installed) and the DHW circulation pump (if installed).
The DHW circulation pump ensures that hot water is available at the draw-off
points at short notice.
The time program comprises four time phases, i.e.
H for central heating, up to four changes between "Standard room
temperature" and "Reduced room temperature" can be programmed.
H DHW heating and DHW circulation pump can be activated/deactivated up to
four times per day.
At the factory, phase 1 is set for all weekdays, i.e. in this phase all rooms are
heated at standard room temperature, DHW is produced and the DHW
circulation pump is activated.
The following keys are allocated to the time programs:
Key
Time program for
A
Central heating
B
DHW heating
C
DHW circulation pump
You can select identical time programs for all weekdays or individual ones for
each weekday.
Take the response time of your heating system into consideration when
setting the time programs. Select correspondingly earlier start-up and
shutdown times.

Modifying and scanning time programs

Basic factory setting
Standard room temperature:
from 6.00 to 22.00 hrs
On:
5.30 to 22.00 hrs
On:
5.30 to 22.00 hrs