Item
Setting range
1
AE
0-31
2
AE(TS)
46-31
Purpose
Setting
Function
Used to set the AE and the limit value in AE (Toner
(Purpose)
save).
Operation/procedure
1. Touch the item to be adjusted.
The adjustment item and the currently set value are highlighted.
2. Enter the set value with the 10-key.
Item
Setting range
1
AE
2
TEXT
3
TEXT/PHOTO
0 - 2
4
PHOTO
5
SUPER PHOTO
46-39
Purpose
Setting
Function
Used to switch the FAX send image quality.
(Purpose)
Enter the set value with the 10-key.
Item
Content
0
HAIRLINE
Original with pencil lines
and thin lines
1
PRINTER
Printed original
Default
0
Default
1
Setting range
Default
0 - 1
AR-M236/M276/M237/M277 SIMULATION 8 - 36
48
48-1
Purpose
Adjustment
Function
Used to adjust the copy mode magnification ratio (main
(Purpose)
scanning direction, sub scanning direction).
Section
Image processing
Item
Picture quality
Operation/procedure
1. Touch the item to be set.
The item and the currently set value are highlighted.
2. Press the [START] key.
The display is shifted to the copy menu.
3. Select the paper feed tray and the print density, and enter the
adjustment value with the 10-key.
4. Press the [START] key.
Copying is started.
Item
1
F-R
2
SCAN
3
SPF/RSPF
(SIDE1)
4
SPF/RSPF
(SIDE2)
5
DUPLEX
Note: When this simulation is canceled, the display is shifted to the ini-
tial menu, but the machine is not reset.
48-2
Purpose
Adjustment
Function
Used to adjust the scanner mode magnification ratio
(Purpose)
(main/sub scanning direction).
Section
Image processing
Item
Picture quality
Operation/procedure
0
1. Touch the item to be set.
The item and the currently set value are highlighted.
2. Press the [START] key.
The display is shifted to the copy menu.
3. Select the paper feed tray and the print density, and enter the
adjustment value with the 10-key.
4. Press the [START] key.
Copying is started.
Content
Main scanning magnification
ratio adjustment
Sub scanning magnification
ratio adjustment
SPF/RSPF surface sub scan
magnification ratio
SPF/RSPF back surface sub
scan magnification ratio
DUPLEX sub scanning
magnification ratio adjustment
Setting
Default
range
1-99
50
60
50