B. Mechanism Section - Sharp AR-M236 Service Manual

Hide thumbs Also See for AR-M236:
Table of Contents

Advertisement

(3) Developing bias voltage adjustment (SIM 8-1)
1) Execute SIM 8-1.
SIMULATION 8-1
DV BIAS COPY SETTING. INPUT VALUE 200-550, AND PRESS
START.
1: AE
400
2: TEXT
450
3: TEXT/PHOTO
450
4: PHOTO
450
5: SUPER/PHOTO
400
6: TONER SAVE
376
Press the [START] key.
SIMULATION 8-1
DV BIAS COPY SETTING. EXECUTING...
5:SUPER PHOTO
2) Touch the exposure mode to be changed.
The current set value is displayed.
3) Enter the set value with the 10-key.
4) Press the [START] key.
Output is made with the entered value, and the display returns to
the original state.
<Adjustment specification>
Item
Content
1
AE
AE
2
TEXT
Character
3
TEXT/PHOTO
Character/Photo
4
PHOTO
Photo
5
SUPER/PHOTO
Super photo
6
TONER SAVE
Toner save
(4) Grid bias voltage adjustment (High mode) (SIM 8-2)
1) Execute SIM 8-2.
SIMULATION 8-2
MHV(H) COPY SETTING. INPUT VALUE 1-8, AND PRESS START.
1: AE
3
2: TEXT
5
3: TEXT/PHOTO
5
4: PHOTO
5
5: SUPER/PHOTO
3
6: TONER SAVE
2
Press the [START] key.
SIMULATION 8-2
MHV(H) COPY SETTING. EXECUTING...
5:SUPER PHOTO
2) Touch the exposure mode to be changed.
The current set value is displayed.
3) Enter the set value with the 10-key.
4) Press the [START] key.
Output is made with the entered value for 30sec, and the display
returns to the original state.
<Adjustment specification>
Item
1
AE
AE
2
TEXT
Character
3
TEXT/PHOTO
Character/Photo
4
PHOTO
Photo
5
SUPER/PHOTO
Super photo
6
TONER SAVE
Toner save
Min. unit: –25V increment
400
1/1
Press the [CUSTOM SETTINGS] key.
Or after completion of operation.
400
Installation
Default
range
200-550
400 (–400V)
450 (–450V)
450 (–450V)
450 (–450V)
400 (–400V)
376 (–376V)
3
1/1
Press the [CUSTOM SETTINGS] key.
Or after completion of operation.
3
Setting
Content
Default
range
1-8
3 (–530V)
5 (–580V)
5 (–580V)
5 (–580V)
3 (–530V)
2 (–505V)
AR-M236/M276/M237/M277 ADJUSTMENTS 7 - 2
(5) Grid bias voltage adjustment (Low mode) (SIM 8-3)
1) Execute SIM 8-3.
SIMULATION 8-3
MHV(L) COPY SETTING. INPUT VALUE 1-8, AND PRESS START.
1: AE
3
2: TEXT
5
3: TEXT/PHOTO
5
4: PHOTO
5
5: SUPER/PHOTO
3
6: TONER SAVE
2
Press the [START] key.
SIMULATION 8-3
MHV(L) COPY SETTING. EXECUTING...
5:SUPER PHOTO
2) Touch the exposure mode to be changed.
The current set value is highlighted.
3) Enter the set value with the 10-key.
4) Press the [START] key.
Output is made with the entered value for 30sec, and the display
returns to the original state.
<Adjustment specification>
Item
Content
1
AE
AE
2
TEXT
Character
3
TEXT/PHOTO
Character/Photo
4
PHOTO
Photo
5
SUPER/PHOTO
Super photo
6
TONER SAVE
Toner save
Min. unit: -25V increment

B. Mechanism section

(1) Print start position adjustment
1) Execute SIM 50-5.
SIMULATION 50-5
LEAD EDGE ADJUSTMENT(PRINT). INPUT VALUE 0-99, AND PRESS
START.
1: TRAY1
53
2: OPTION
53
3: MANUAL
53
4: DUPLEX
53
Press the
Press the
[START] key.
[P] key.
READY TO COPY
1: TRAY1
Press the
[START] key.
COPIES IN PROGRESS.
During execution of copying the [CUSTOM SETTING] key and
the [INTERRUPT] key are disabled.
2) Touch the item to be adjusted.
The item and the currently set value are highlighted.
3) Press the [P] key.
The display is shifted to the copy menu.
4) Select the paper feed tray, the print density, and the duplex mode.
Enter the adjustment value with the 10-key.
3
1/1
Press the [CUSTOM SETTINGS] key.
Or after completion of operation.
3
Setting
Default
range
1-8
3 (–400V)
5 (–450V)
5 (–450V)
5 (–450V)
3 (–400V)
2 (–375V)
53
1/1
Press the
[CUSTOM SETTINGS]
key.
50
Press the [CA] key.
Or after completion
of operation.
After canceling JAM
(After pick-up,
the [C] key is disabled.)
50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-m277Ar-m276Ar-m237

Table of Contents