210
170
2
430
200
1
2
4
1
4
1313401A_EN
1
24
1
25
3
26
1
27
3
2
Short standpipe 1 by 210 mm and shape as
shown. Bend connection piece 2 by 90°.
Remove fuel-tank vent line 1 from bracket
and cut off approx. 200 mm before fuel tank
connection piece. Remove section on
connection piece.
1 16-24 mm dia. clamp
2 Fuel-tank vent line
3 Fuel standpipe
4 Dia. 3.5 x 4.5 mm hose section; 8 mm dia.
Caillau clamp
When installing, align standpipe of fuel
standpipe 2 to fuel tank bottom.
1 16-24 mm dia. clamp [2x]
2 Fuel standpipe
3 10 mm dia. Caillau clamp
4 Fuel line
Fiat 500
Removing
fuel
Cutting
point
Premount-
ing fuel
standpipe
Installing
fuel
standpipe