BDVT Series Direct Vent Gas Fireplace

Glass Information

Only glass approved by CFM Specialty
Home Products should be used on this
fireplace.
The use of any non-approved replacement glass will
void all product warranties.
Care must be taken to avoid breakage of the glass.
Do not operate appliance with glass front
removed, cracked or broken.
Replacement glass (complete with gasket) is
available through your CFM Specialty Home
Products dealer and should only be installed by
a licensed qualified service person.

Louvre Removal

The top louvre
panel is removed
by lifting the
panel vertically
and pulling it
away from the
appliance. (Fig.
34)
The lower access
door is hinged
along the bottom
edge and is
folded down to
FP1227
allow access.
Fig. 34 Remove top louvre assembly.

Window Frame Assembly Removal

1. Turn the fireplace OFF (including the pilot)
2. If the unit has been operating allow time for the
components to cool.
3. Remove the top louvre assembly.
4. Open the lower louvre panel.
5. Release the two clamps securing the lower edge of
the frame by pulling down on the handles. (Fig. 35)
6. Tilt the glass frame out slightly at the bottom, lift the
frame up and away from the fireplace.
7. To replace the glass frame reverse the procedure.
20

Operating Instructions

2.
Louvre
1.
Glass Panel
Window
Frame
Assembly
Fig. 35 Window frame assembly removal.

Glass Cleaning

It is necessary to periodically clean the glass. During
start-up condensation, which is normal, forms on the
inside of the glass. This condensation causes lint, dust
and other airborne particles to cling to the glass surface.
Also initial paint curing may deposit a slight film on
the glass. It is therefore recommended that the glass
be cleaned two or three times with a non-ammonia
based household cleaner and warm water (We
recommend gas fireplace glass cleaner) within the
first few weeks of operation.
After the initial cleaning process the glass should be
cleaned two or three times during each operating
season depending on the environment in the house.
Clean the glass after the first two weeks
of operation.
Do not clean glass when hot.
Do not use abrasive cleaners.
Do not strike or slam glass.
Lower Clamps
Window
Frame
Assembly
Pull
Clamp
Push
Hook
Clamp
Handle
FP1228
10003358

Hide quick links: