Gas Line Installation

When purging gas line, the front window
frame assembly must be removed.
The gas pipeline can be brought in through the rear of
the fireplace as well as the bottom. Knockouts are
provided on the bottom behind the valve to allow for
the gas pipe installation and testing of any gas connec-
tion. It is most convenient to bring the gas line in from
the rear right side of the valve as this allows fan instal-
lation or removal without disconnecting the gas line.
The gas line connection can be made with properly
tinned 3/8" copper tubing, 3/8" rigid pipe or an
approved flex connector. Since some municipalities
have additional local codes, it is always best to con-
sult your local authority and the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 in the USA or the CSA-
B149.1 installation codes.
1/2" Gas Supply
Fig. 5 Typical gas supply installation.
Always check for gas leaks with a mild
soap and water solution. Do not use an
open flame for leak testing.
The gas control is equipped with a captured screw type
pressure test point, therefore it is not necessary to
provide a 1/8" test point up stream of the control.
When using copper or flex connector use only ap-
proved fittings. Always provide a union when using
black iron pipe so that the gas line can be easily
disconnected for burner or fan servicing . See gas
specifications for pressure details and ratings.
The fireplace valve must not be subjected to any test
pressures exceeding 1/2 psi. Isolate or disconnect this
or any other gas appliance control from the gas line
when pressure testing.
10003358
1/2" NPT X 1/2" Flare Shut-off Valve
3/8" Flex line
(from valve)
BDVT Series Direct Vent GaS Fireplace
Installation:
1. Thread the wiring through holes on the end panels
of appliance. Take care not to cut wire or insulation
on metal edges. Route the wire to a conveniently
located receptacle box.
2. Attach the wire to the ON/OFF switch and install the
switch into the receptacle box.
3. Connect the other ends of the wire to the gas control
valve. (Fig. 6)
Fig. 6 Remote switch wiring diagram.

Alternate Switch Location

FP297A
The remote switch can be installed on the front/side of
the access door. Simply mount the switch to the
bracket provided and screw the bracket to either side of
the frame, lining up the screws with the pre-punched
holes. (Fig. 7)
Fig. 7 Alternate switch location.
Do not wire the remote ON/OFF wall
switch for the gas fireplace to the 120
volt power supply.
Remote ON/OFF Switch
Remote ON/OFF
Switch or Thermostat or
Remote Control
TP
TH
TP
TH
Gas
Control
Valve
FP1224
FP1024
7