BDVT Series Direct Vent Gas Fireplace
START
Gas Supply On
YES
Pilot Lights With Piezo
Ignitor
Pilot Stays Lit
YES
Pilot Lights Main Burner
YES
SYSTEM OK
26
Troubleshooting Honeywell Millivolt Valve
Remove Window Frame Assembly Before Service Work
YES
CHECK
•
Supply Line Hooked Up
NO
•
Shutoff Valve Open
•
Lockout Has Engaged. Wait 60
Seconds And Try Again.
•
For Spark At Electrode While
Depressing Piezo
NO
1/8" Gap To Pilot Hood Needed.
•
All Wiring Connections
•
Replace Piezo Ignitor
•
For Air In The Lines
•
Thermopile Needs A Min.
325mv. Adjust Pilot Flame
Height.
•
All Wiring Connections
NO
•
Replace Thermopile
•
Thermocouple Needs A Min. Of
14mv
•
Defective Valve. Turn To Pilot,
Meter Should Read Greater
Than 100mv. If Not, Replace.
•
Valve Is Turned On
•
Wall Switch Is Not Turned On.
Watch For Grounded Wires!
NO
•
Thermopile Needs A Min. 325mv.
•
Plugged Burner Orifice