A
A
D
Code plugs
12kW NG
with internal diverter valve - 1118 12kW NG
12kW LPG
with internal diverter valve - 1119 12kW LPG
24kW NG
with internal diverter valve - 1114 24kW NG
24kW LPG
with internal diverter valve - 1115 24kW LPG
56
LPG CONVERSION
1.1
2.1
3.1
E
with external diverter valve - 1116
with external diverter valve - 1117
with external diverter valve - 1110
with external diverter valve - 1111
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 12i/24i System
1.2
L. P. G. CONVERSION
I S O LATE
SUPPLY AND REMOVE OUTER CASE
AS SHOWN IN THE INSTALLATION,
C O M M I S S I O N I N G & S E RVI C I N G
INSTRUCTIONS
THE CONVERSION MUST BE CARRIED OUT
BY A COM PETE NT PE R SON. IT M UST NOT
B E AT T E M P T E D U N L E S S T H E P E R S O N
2.2
C A R R Y I N G O U T T H E C O N V E R S I O N I S
EQUIPPED WITH A COMBUSTION ANALYSER
C O N F O R M I N G
COMPETENT IN ITS USE.
Important: The appliance shall not be installed
into a room or internal space below ground
level when it is intended for use with LPG
(propane - G31). This does not preclude the
installation into a room or space which is a
basement on one side of the building but open
2.3
to ground on the opposite side.
Installation Regulations
In addition to those specified in the main
booklet the following standard applies when
converting to an LPG appliance: BS 5842
Domest ic
Installations.
All conversions will require the air gas ratio to
be set correctly for the gas used. The
B
procedure for setting the air gas ratio is at
the rear of these instructions.
1. Lowering boiler control to service
position
Remove boiler case, as described on page 36.
1.1 Remove screw (A) from retaining bracket.
1.2 Lower control panel into service position.
2. Gas valve
Isolate gas supply at boiler gas cock.
2.1 Remove wire clip from gas valve outlet then
pull valve outlet elbow free from gas valve.
2.2 Undo bottom gas connection to gas valve.
2.3 Undo two securing screws (B) on the
underside of casing.
Pull valve up and forward out of boiler.
Disconnect electrical connections.
Fit plastic retaining nut to the outlet of the
3.2
gas valve from the kit and hand tighten.
Replace valve with new seals.
Check for gas soundness.
3. Code plug
3.1 Remove 3 screws (D) retaining plastic
cover at rear of control box and remove.
3.2 Replace code plug (E) with new one
supplied with conversion kit.
Replace plastic cover.
Place control in normal position and secure
with screw.
TH E AI R / GAS R ATI O M U ST B E
R ESET AFTE R CONVE R SION. TH E
P R O C E D U R E C AN B E F O U N D I N
THE SETTING THE AIR/GAS RATIO
SECTION OF THIS MANUAL.