Granit 1980I Industrial Full Range Corded Scanner Product Specifications - Honeywell Xenon 1900 User Manual

Hide thumbs Also See for Xenon 1900:
Table of Contents

Advertisement

Granit 1980i Industrial Full Range Corded Scanner Product Specifications

Parameter
Dimensions (Typical):
Height
Length
Width
Weight
Illumination LED:
Peak Wavelength
Aiming:
Peak Wavelength Laser
Optical Power Laser
Image Size
Skew Angle
Pitch Angle
Motion Tolerance:
Symbol Contrast
Voltage Requirements
Current Draw @5VDC
Power Supply Noise Rejection
Temperature Ranges:
Operating
Storage
Humidity
Mechanical Drop
Vibration
ESD Tolerance
Sealant Rating
Specification
7.7 in. (195.6mm)
5.2 in. (132.1mm)
2.9 in. (73.7mm)
11.8 oz. (335g)
617nm + 18nm (amber LED)
IEC 62471: "Exempt Risk Group"
650nm
IEC 60825-1: "Class 2"
<1mW
1280 x 800 pixels
+80° typical, 200 lux, EAN/UPC
+70°typical, 200 lux, EAN/UPC
30 inches per second typical on 13 mil UPC/EAN bar code 8 in. from scanner nose
1D codes 30% or greater (typical, 200 lux, 13 mil)
2D codes 40% or greater (typical, 200 lux, 20 mil)
4 - 5.5 VDC at input connector
Scanning
Standby
470mA, 2.35W
100mA, 0.5W
Maximum 100mV peak to peak, 10 to 100 kHz
-22°F to +122°F (-30°C to 50°C)
-40°F to +158°F (-40°C to 70°C)
0 to 95% non-condensing
Operational after 50 drops from 6.5 feet
(1.98m) to concrete at 23°, -30°, and 50°C
Complies with MIL-STD-810G, Method 514.6, Annex C
Up to 20kV direct air
Up to 8 kV indirect coupling plane
IP65
13 - 5

Advertisement

Table of Contents
loading

Table of Contents