When the output sequence is Off, the bar code data is output to the host as the scanner decodes it. Default = Off.
Note: This selection is unavailable when the Multiple Symbols Selection is turned on.
Required
*Off

Multiple Symbols

When this programming selection is turned On, it allows you to read multiple symbols with a single pull of the scanner's trigger.
If you press and hold the trigger, aiming the scanner at a series of symbols, it reads unique symbols once, beeping (if turned on)
for each read. If using a Granit scanner, the scanner also vibrates. The scanner attempts to find and decode new symbols as
long as the trigger is pulled. When this programming selection is turned Off, the scanner will only read the symbol closest to the
aiming beam. Default = Off.
On

No Read

With No Read turned On, the scanner notifies you if a code cannot be read. If using an EZConfig-Scanning Tool Scan Data
Window (see page 11-3), an "NR" appears when a code cannot be read. If No Read is turned Off, the "NR" will not appear.
Default = Off.
On
If you want a different notation than "NR," for example, "Error," or "Bad Code," you can edit the output message (see
Formatting
beginning on page 7-1). The hex code for the No Read symbol is 9C.
On/Not Required
* Off
* Off
Data