Serial Trigger Mode

You can activate the scanner either by pressing the trigger, or using a serial trigger command (see
12-3). When in serial mode, the scanner scans until a bar code has been read or until the deactivate command is sent. The
scanner can also be set to turn itself off after a specified time has elapsed (see

Read Time-Out

Use this selection to set a time-out (in milliseconds) of the scanner's trigger when using serial commands to trigger the
scanner. Once the scanner has timed out, you can activate the scanner either by pressing the trigger or using a serial trig-
ger command. After scanning the Read Time-Out bar code, set the time-out duration (from 0-300,000 milliseconds) by
scanning digits on the

Presentation Mode

Presentation Mode uses ambient light and scanner illumination to detect bar codes. When in Presentation Mode, the LEDs
remain dim until a bar code is presented to the scanner, then the aimer turns on and the LEDs turn up to read the code. If the
light level in the room is not high enough, Presentation Mode may not work properly
Note: If you are using a cordless charge base in Presentation Mode, the battery will not charge unless the power supply is
plugged into the base's auxiliary power port.
Scan the following bar code to program your scanner for Presentation Mode.
Programming Chart
inside the back cover, then scanning Save. Default = 30,000 ms.
Read
Read Time-Out
Presentation Mode
* High
Trigger Commands
Time-Out, which follows).