ASSEMBLY
Figure 180 Installing glow plugs
Figure 181 Installing alternator
Figure 182 Adjusting alternator and fan belt
Service Manual Mitsubishi SL-Series diesel engines
Version 08/2004
Adjusting plate bolt
Apply 10 kgf (22 lbf) [98
N] force midway
between crankshaft
pulley and alternator
pulley.
ASSEMBLY

27 Electrical System

27.1 Glow plug installation

Install the glow plug in position in the precombustion
chamber and tighten it to the specified torque
Tightening torque

27.2 Alternator installation

1.
Put the alternator in position. Install the adjusting
plate bolt in position to hold the alternator in
position.
2.
Put the belt in position on the pulley. Move the
alternator away from the engine to make an
adjustment to the belt.
3.
Tighten the bolts.
4.
Make sure the deflection (tension) of the belt is
correct.
Deflection under 10 kgf
(22 lbf) [98 N] force
ENGLISH
Electrical System
1,75 ± 0,25 kgf·m
(12.7 ± 1.8 lbf·ft)
[17,2 ± 2,5 N·m]
Unit: mm (in.)
10 to 12
(0.4 to 0.5)
109 / 195