Cooling System (Standard); Electrical System - Mitsubishi S3L Service Manual

Sl series
Hide thumbs Also See for S3L:
Table of Contents

Advertisement

SERVICE DATA
Item
Temperature at which valve
starts opening
Thermostat
Temperature at which valve lift
is more than 8 mm (0.3 in.)
Temperature at which switch is
Thermo-
switch
Resistance at oil temperature
of 120°C (284°F)
At 50°C (122°F)
Resistance
in
At 80°C (176°F)
thermounit
At 120°C (248°F)
Deflection of fan belt under 10 kgf (22 lbf)
[98 N] force applied midway between
alternator pulley and crankshaft pulley
Item
Pinion clearance
Terminal voltage
No-load
charac-
teristics
Brush length
Brush spring tension
Runout of commutator
Diameter of commutator
Undercut of mica
Service Manual Mitsubishi SL-Series diesel engines
Version 08/2004
turned ON
S3L/S3L2
11.5 V
100 A
Current draw
maximum
3 000
rpm
minimum

55.5 Cooling system (standard)

Standard
82 ± 1.5°C
(180 ± 2.7°F)
95°C (203°F)
111 ± 3.5°C
(232 ± 6.3°F)
30 mΩ maximum
80 ± 10 Ω
29.5 ± 2.5 Ω
10 ± 0.3 Ω
10 to 12
(0.4 to 0.5)

55.6 Electrical system

Standard
0.5 to 2.0
(0.020 to 0.079)
S4L/S4L2
11 V
130 A
maximum
3 600
minimum
3.0 kgf
(6.6 lbf)
[29.4 N]
0.03 (0.001 2)
32 (1.26)
0.5 (0.020)
ENGLISH
SPECIFICATIONS
Limit
Limit
Correction-Remarks
Adjust with packing.
Wear limit line
1.8 kgf
(4.0 lbf)
[17.7 N]
0.10 (0.003 9)
Repair or replace.
31 (1.22)
0.2 (0.008)
Unit: mm (in.)
Correction-Remarks
Replace.
Replace.
Replace.
Replace.
Unit: mm (in.)
Test.
Replace.
Replace.
Replace.
Repair.
189 / 195