Getting Started - Keithley 2303 User Manual

High speed
Hide thumbs Also See for 2303:
Table of Contents

Advertisement

A simplified diagram of the power supply is shown in Figure 1-2. Note that it can read back
the output voltage (V
meter
Current Readback Ranges:
Models 2303 and 2303B – Two ranges for current readback: 5A and 5mA. On the 5A
range, display resolution is 100µA, and on the 5mA range, resolution is 0.1µA.
Model 2303-PJ – Two ranges for current readback: 5A and 500mA. On the 5A range,
display resolution is 100µA, and on the 500mA range, resolution is 0.01mA (10µA).
The power supply also has a digital voltmeter (DVM) that is independent of the power supply
circuit. The DVM can measure up to +20V (1mV resolution).
When used with a pulsed load, the power supply can read back peak current, idle current, and
average current. See Section 3 for details. A long integration (up to 60 seconds) function is pro-
vided to measure average current of a low frequency pulse (long period) or a series of pulses.
See Section 4 for details.
Figure 1-2
Simplified power supply diagram
Source
DVM
Voltmeter
) and current (I
). Display resolution for voltage readback is 1mV.
meter
I meter
V-Source
V meter
with I-Limit
Digital

Getting Started

+
_
+
_
1-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2303b2303-pj

Table of Contents