Table 2.2. Installation Environment Requirements
Model
Operating temperature
*8
Storage temperature
Humidity
Floating dust particles
Corrosive gases
Line-noise
resistance
Ambient
specifications
Vibration
resistance
Impact resistance *11
Grounding
*8
: For more details on this, please refer to chapter 3, "Installation Requirements".
*9
: When AC/DC power unit "LDA100W-24-SN, LDA100W-12-SN" (by Cosel) is used.
*10 : To use 1000BASE-T, you should keep its ambient temperature between 0 - 40°C.
*11 : To use 1000BASE-T, you should keep its ambient temperature between 0 - 45°C.
*12 : As for the case of model with multi-signal I/O (BX-100n-DC5000-C02, BX-100n-DC5311-C02), it is the same.
12
BX-100n-DC5000-C01
BX-100n-DC5121-C01*1
0 - 45°C *10
-10 - 60°C
10 - 90%RH (No condensation)
Not to be excessive
None
AC line / ±2kV *9,
Line noise
Signal line / ±1kV (IEC61000-4-4 Level 3,EN61000-4-4 Level 3)
Static
Contact discharge / ±4kV (IEC61000-4-2 Level 2, EN61000-4-2 Level 2)
electricity
Atmospheric discharge / ±8kV (IEC61000-4-2 Level 3, EN61000-4-2 Level 3)
resistance
When HDD is on
Sweep
resistance
When HDD is off *12
10G, half-sine shock for 11 ms in x, y, and z directions
(JIS C60068-2-27-compliant, IEC60068-2-27-compliant)
Class D grounding (previous class 3 grounding), SG-FG / continuity
BX-100n-DC5000-C02
BX-100n-DC5311-C02
0 - 50°C *11
10 - 50Hz / 0.5G
25 min. each in x, y, and z directions
(JIS C60068-2-6-compliant,
IEC60068-2-6-compliant)
10 - 57Hz / semi-amplitude 0.15 mm
57 - 150Hz/2.0G
40 min. each in x, y, and z directions
(JIS C60068-2-6-compliant,
IEC60068-2-6-compliant)