Main Unit Removal; Panel Unit Removal - Epson Stylus PHOTO RX510 Service Manual

Hide thumbs Also See for Stylus PHOTO RX510:
Table of Contents

Advertisement

EPSON Stylus PHOTO RX500/510

4.2 Main Unit Removal

4.2.1 Panel Unit Removal

1.
Remove a USB cable from the Stylus PHOTO RX500/510 unit.
2.
Remove the operation panel from the panel unit.
3.
Remove two screws securing the panel unit.
4.
Remove the panel unit from the printer.
5.
Remove three screws that secure front housing.
6.
Remove front housing from the printer.
7.
Unhook four locations, and remove the decorative panel from the middle housing.
8.
Disconnect a panel harness (CN8) to the panel unit from the main board.
9.
Remove a the panel unit from the Stylus PHOTO RX500/510 unit.
Disassembly and Assembly
Panel Unit
C.B.P Tite 3x6,F/ZN
Tightening torque
:0.3 ± 0.05 N
m
Decorative Panel
Main Unit Removal
Operation Panel
C.B.P Tite 3x8,F/ZN
Tightening torque:0.6 ± 0.1 N
C.B.P Tite 3x10,F/ZN
Tightening torque:0.6 ± 0.1 N
Hook
Figure 4-1. Panel Unit Removal
Revision C
m
m
Front Housing
41