Terminating Tracking Of Targets (Including Reference Targets) - Furuno FAR-2807(-D) series Operator's Manual

Table of Contents

Advertisement

3. TARGET TRACKING (TT)
3.5.2

Terminating tracking of targets (including reference targets)

When the TT has acquired the menu-set number of targets automatically, the
message "TARGET-FULL(AUTO)(or MAN)" appears at the right side of the
screen and no more auto acquisition occurs unless targets are lost. Should this
happen, cancel tracking of less important targets or perform manual acquisition.
Canceling individual targets
By keyboard:
1. Use the trackball to put the cursor (+) on the tracked target, reference target
or lost target you wish to cancel tracking.
2. Press the [TARGET CANCEL] key.
By trackball:
1. With the cursor inside the effective display area, roll the scrollwheel to show
TARGET CANCEL / EXIT in the guidance box.
2. Put the cursor (+) on the tracked target, reference target or lost target you
wish to cancel tracking.
3. Push the left button to cancel tracking on the target selected.
4. To finish, push the right button.
Canceling tracking on all targets
1. Right-click the TT ACQ MODE box at the right side of the screen to show the
TT TARGET menu.
2. Select 2 ALL CANCEL and YES.
3. Push the left button to cancel tracking on all tracked targets.
3-6
[TT TARGET MENU]
1 TT SELECT
MANUAL100/
AUTO 25/
AUTO 50/
AUTO 75/
AUTO 100
3 ALL CANCEL
NO/YES
3 REF TARGET VECTOR
OFF/ON
TT TARGET menu