Troubleshooting With Error Display; Abnormal Freezer Sensor Error - Kenmore 795.51022.001 Service Manual

Table of Contents

Advertisement

2. Troubleshooting With Error Display

1) Abnormal Freezer Sensor Error

NO.
CHECKING FLOW
Check for a loose connection in CON6
1
Unplug connector and check between
White to White as is shown in the picture.
2
1) Remove the Cover Sensor.
2) Cut Sensor and check resistance value.
3
RESULT & SERVICE ACTION
Result
Firmly plugged
Loose
Result
0 Ù
Short
OFF
Open
Other
Normal
Temperatures when unit is energized
(Refer to Temperature Chart #1)
Result
0 Ù
Short
Open
OFF
- 79 -
Service Action
Go to Step 2
Service Action
Go to Step 3
Go to Step 4
Check the Temperature
and Resistance
(Temperature Chart #1)
Go to Step 6
Service Action
Replace Product
Change the sensor

Hide quick links: