3) Abnormal Refrigerator Sensor Error (2)
NO.
CHECKING FLOW
1) Remove the Cover sensor.
2) Cut sensor and stripe terminals.
3) Make a short in striped terminals.
4) Maker measurement.
4
1) Reconnect CON 7.
2) Reset Refrigerator.
3) Execute DISPLAY CHECK MODE
4) All LED's on?
5
Resistance Values are according to Temperature
Chart table?
6
RESULT & SERVICE ACTION
Result
0 Ù
Short
Open
OFF
Result
Normal
YES
Same
Different
ERROR
Result
Normal
YES
Sensor
NO
Abnormal
Sensor
- 84 -
Service Action
Change the sensor
Replace Product
Service Action
Explain to costumer
Replace Main PCB
Proceed acord the
displayed error
Service Action
Replace Main PCB
Replace Sensor