15) Refrigerator Lamp is not working
NO.
CHECKING FLOW
1
Reset Refrigerator.
Check the Refrigerator Door S/W activating
movement.
2
Check for any loose connection in Refrigerator
Door S/W.
3
Unplug connector from Door S/W, then check
between terminals.
4
AC Part
Reconnect Door S/W and check voltage.
5
AC Part
DC Part
- 104 -
RESULT & SERVICE ACTION
Result
Tight
Abnormal
movement
Free
Normal
movement
Result
Firmly plugged
Loose
Lever S/W
0 Ù
Go to Step 5
Released
Other
Replace Door S/W
Go to Step 5
OFF
Pressed
Other
Replace Door S/W
Lever S/W
0~5 Vac
Lamps
Released
Other
Go to Step 6
Pressed
Explain to customer
(NOTE: Lamp must
110~127 Vac
be OFF)
0~5 Vac
Go to Step 6
Other
Go to Step 5
Service Action
Change Door S/W
Go to Step 2
Service Action
Go to Step 4
Service Action
Service Action
Action
ON
Go to Step 5
OFF
Replace Door S/W