2) Abnormal Refrigerator Sensor Error (1)
NO.
CHECKING FLOW
Check for a loose connection in CON7
1
Unplug connector and check between
White to White as is shown in the picture.
2
1) Remove the Control Box in Refrigerator sensor.
3
2) Check for any loose connection.
3) Turn on the Refrigerator.
RESULT & SERVICE ACTION
Result
Firmly plugged
Loose
Result
0 Ù
Short
OFF
Open
Other
Normal
Connectors must be firmly .connected, and wires don't be
have any damage.
Next Action: Go to Step 4.
- 81 -
Service Action
Go to Step 2
Service Action
Go to Step 3
Check the Temperature
and Resistance
(Temperature Chart #2)
Go to Step 7