Dust Control Turn-Off Delay Adjustment:
FACTORY DEFAULT: 3 (5 seconds)
RANGE: 1 - 9 (3 – 11 seconds)
The amount of time that the dust control continues to run after the foot pedal returns to neutral is adjustable. To select the desired delay:
1
Turn the main power key switch to the off position.
2
Press and hold the dust control switch.
3
While holding the dust control switch turn the main power key switch to the on position.
4
Continue to hold the dust control switch until all indicators except the dust control indicator turn off (approximately two seconds).
5
Release the dust control switch.
6
The status display will now show a number from 1 to 9. Pressing and releasing the dust control switch will increase the displayed value until
9 is reached. The next press will return to 1. Each increment represents one second with 1 equal to three seconds.
7
To save the new setting, turn the main power key switch to the off position.
8
The new setting will be saved and will remain in effect until it is changed again.
Shaker Duration Adjustment:
FACTORY DEFAULT: 5 (20 seconds)
RANGE: 1 - 9 (12 – 28 seconds)
The amount of time that the shaker runs once it has been activated is adjustable. To select the desired duration:
1
Turn the main power key switch to the off position.
2
Press and hold the shaker switch.
3
While holding the shaker switch turn the main power key switch to the on position.
4
Continue to hold the shaker switch until all indicators except the shaker indicator turn off (approximately two seconds).
5
Release the shaker switch.
6
The status display will now show a number from 1 to 9. Pressing and releasing the shaker switch will increase the displayed value until 9 is
reached. The next press will return to 1. Each increment represents two seconds with 1 equal to twelve seconds.
7
To save the new setting, turn the main power key switch to the off position.
8
The new setting will be saved and will remain in effect until it is changed again.
Hopper Door Open/Close Duration Adjustment:
FACTORY DEFAULT: 1 (2.0 seconds)
RANGE: 1 - 9 (2.0 – 4.0 seconds)
The amount of time the valves that open or close the hopper door remain on when automatically opening or closing the door is adjustable. To select
the desired duration:
1
Turn the main power key switch to the off position.
2
Press and hold the hopper door open switch.
3
While holding the hopper door open switch turn the main power key switch to the on position.
4
Continue to hold the hopper door open switch until all indicators except the hopper door open indicator turn off (approximately two seconds).
5
Release the hopper door open switch.
6
The status display will now show a number from 1 to 9. Pressing and releasing the hopper door open switch will increase the displayed value
until 9 is reached. The next press will return to 1. Each increment represents 0.25 second with 1 equal to two seconds.
7
To save the new setting, turn the main power key switch to the off position.
8
The new setting will be saved and will remain in effect until it is changed again.
PROGRAMMABLE CONTROL OPTIONS
FORM NO. 56043126 - CR 1100, CR 1200 - 59