Honeywell PM42 User Manual page 95

Hide thumbs Also See for PM42:
Table of Contents

Advertisement

Media Settings (continued)
Setting
Media Length
Clip Default
Start Adjust
Stop Adjust
Media Calibration
Mode
Length (Slow
Mode)
PM42 Mid-Range Printer User Manual
Description
Sets the length of the printable area measured from
one edge of the label to the edge that is closest to
the printhead. Unit of measurement is defined in the
Unit of Measurement parameter.
*935-044-001*
Honeywell
16201 25th Ave W
Lynnwood WA 98087
Determines if the printer prints items outside the
printable area of the label.
When this is set to Off, the printer returns an error if
any part of a bar code label cannot be printed
because that part extends beyond the printable
area. When this is set to On, the printer prints all bar
code labels, but may also print unreadable,
incomplete labels.
Sets the length of media the printer feeds (positive
value) or retracts (negative value) before printing a
label. Unit of measurement is defined in the Unit of
Measure parameter. Range is -9999 to +9999.
Sets the length of media the printer feeds (positive
value) or retracts (negative value) after printing a
label. Unit of measurement is defined in the Unit of
Measure parameter. Range is -9999 to +9999.
Selects the mode the printer uses to calibrate
media. Use Slow if the printer has trouble identifying
gaps or marks in media.
If Media Calibration Mode is set to Slow, the printer
prints the media length plus 10 mm. This value sets
an additional amount of media to be printed. Unit of
measurement is defined in the Unit of Measurement
parameter. Range is 0 to 3200.
Media
length
Appendix B — Default Settings
Default
Variable
Off
0
0
Fast
0
87