[ NORMAL ]
The charger will stop the discharging process every minute to calculate the average resistance.
[ LINEAR ]
The charger will discharge the pack, stopping once after 3 minutes to calculate the internal resistance.
DISCHARGE MODE FOR THE POLARON EX CHARGER
LiPo, LiIon, LiFe
NiCd, NiMH, Pb
In the LINK mode, the packs should have the same voltage, capacity and number of cells.
Differences in these charging parameters can cause damage to the batteries.
* Please install the balance cable to CH1, CH2.
NORMAL
Normal discharge.
LINEAR
The preset current is maintained throughout the discharge process.
LINK
The packs with the same numb er of cells and capacity can be
dischar ged simultaneously.
AUTO
The charger will automatically adjust the discharging conditions.
NORMAL
Normal discharge process.
LINEAR
The preset current is maintained throughout the discharge process.
This page (left) shows the battery check process with the balancer
connected to the charger.
Tapping the Enter
NUMBER OF CELLS CHECKING
After connecting the balance board, the charger can then check
the number of cells. If the number of cells is incorrect, tap the ESC
button to return to the previous page and re-check the parameters.
With the correct number of cells, the next page will automatically
be accessed.
To initiate without a balance board, the number of cells should be
determined and manually entered. After tapping the Enter button,
the charger will then immediately initiate the discharge process.
button will ac cess the next page and
cause the charger to automatically initiate
the charge process.