–– INDOOR UNIT ––
Model
CS-W24BD2P
CS-W28BD2P
CS-W34BD2P
CS-W43BD2P
CS-W50BD2P
Before using your air-conditioner, please
read this operating instructions carefully
and keep it for future reference.
MATSUSHITA ELECTIRC (TAIWAN) CO.,LTD
579 , YUAN SAN ROAD , CHUNG-HO , TAIPEI HSIEN , TAIWAN

OPERATING INSTRUCTIONS

–––––––––––––––– OUTDOOR UNIT ––––––––––––––––
Heat Pump Model
(220~240V, 50Hz, 1 Phase)
CU-W24BBP5
CU-W28BBP5
(380~415V, 50Hz, 3 Phase)
CU-W28BBP8
CU-W34BBP8
CU-W43BBP8
CU-W50BBP8
Cooling Model
(220~240V, 50Hz, 1 Phase)
CU-V24BBP5
CU-V28BBP5
(380~415V, 50Hz, 3 Phase)
CU-V24BBP8
CU-V28BBP8
CU-V34BBP8
CU-V43BBP8
CU-V50BBP8
ENGLISH ............................................... P. 001
PORTUGUÊS ........................................ P. 016
DEUTSCH .............................................. P. 031
FRANÇAIS ............................................. P. 046
NEDERLAND ......................................... P . 061
ITALIANO ............................................... P. 076
GREEK ................................................... P. 091
ESPAÑOL ............................................... P. 106
RUSSIAN ............................................... P. 121

Air Conditioner

P. 015
P. 030
P. 045
P. 060
P. 075
P. 090
P. 105
P. 120
P. 136

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic CS-W24BD2P

  • Page 1: Air Conditioner

    Air Conditioner OPERATING INSTRUCTIONS –––––––––––––––– OUTDOOR UNIT –––––––––––––––– –– INDOOR UNIT –– Model Heat Pump Model Cooling Model CS-W24BD2P (220~240V, 50Hz, 1 Phase) (220~240V, 50Hz, 1 Phase) CS-W28BD2P CU-W24BBP5 CU-V24BBP5 CS-W34BD2P CU-W28BBP5 CU-V28BBP5 CS-W43BD2P CS-W50BD2P (380~415V, 50Hz, 3 Phase) (380~415V, 50Hz, 3 Phase)
  • Page 2: Table Of Contents

    CONTENTS 1. Applicable Model No. Table ............. 2 2. Safety Precautions ................3 Installation Precautions ......................3 Operation Precautions ......................4 3. Name Of Each Part (Main Unit) ................4. Wired Remote Control ..............6 4-1 Name and function of each part ..................6 4-2 How to operate (without timer operation) ......................
  • Page 3: Applicable Model No. Table

    1. APPLICABLE MODEL NO. TABLE Power source Indoor unit Ountdoor unit Type Fre- model name model name Phase Voltage quency CS-W24BD2P CU-W24BBP5 Single 50Hz 220 240V CS-W28BD2P CU-W28BBP5 Single 220 240V 50Hz CS-W28BD2P CU-W28BBP8 3 Phase 380 415V 50Hz Heat...
  • Page 4: Safety Precautions

    2. SAFETY PRECAUTIONS Before operating, please read the following “Safety Precautions” carefully. To prevent personal injury, injury to others and property damage, the following instructions must be followed. ■ Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classified as follow: WARNING This sign warns of death or serious injury.
  • Page 5: Operation Precautions

    Operation Precautions WARNING Do not repair the unit by Do not expose directly to yourself. the cold air for a long period. Do not use naked flames Only use the correct type near the refrigerant. of fuse. Do not insert finger or If abnormal conditions (burnt smell, etc) occur, other objects into the...
  • Page 6: Name Of Each Part (Main Unit)

    3. NAME OF EACH PART (MAIN UNIT) Indoor unit Outlet grille Air is discharged from here. AIR SWING TIMER OPE- TEMP Wired remote control SPEED RATION LOCAL MANUAL (Refer to page 6 for operation OFF/ON Inlet grille details.) Air is drawn into the indoor unit from here. Outdoor unit Power supply Current leakage...
  • Page 7: Wired Remote Control

    4. WIRED REMOTE CONTROL 4-1 Name and function of each part Display panel 1 REMOTE The OFF/ON button cannot be used. SWING TIMER OPE- REMOTE RATION TEMP SPEED LOCAL CHECK LOCAL AUTO AUTO ADDRESS All remote control functions can be used. HEAT A/C No.
  • Page 8: How To Operate (Without Timer Operation)

    4-2 How to operate (without timer operation) NOTES Once a button has been pressed to make a setting, the setting will be retained even though the OFF/ON button is SWING TIMER OPE- pressed to stop and restart the operation. RATION TEMP SPEED LOCAL...
  • Page 9: How To Operate (With Timer Operation)

    4-3 How to operate (with timer operation) Set the clock and other operation details (refer to page 7 for operation setting details) before setting the timer. Setting the current time Example: setting the time to 10:36 a.m. Press A to activate the setting time. TIMER SWING OPE-...
  • Page 10: Maintenance

    5. MAINTENANCE CAUTION CAUTION • Before washing the air filter, stop the unit operation and turn off the circuit breaker. The fan rotates at high speed may cause injury. • Do not wash the unit with water. Water may cause short circuit or electric shock. •...
  • Page 11: Proper Use

    Cleaning the outer cover • Wipe with a dry soft cloth or a cloth slightly moistened Important notes: with water or neutral detergent solution. • Wiping with benzine or thinner could cause discoloration or flaking of the unit’s finishing. • If use chemically treated cloth to clean the unit, please read and follow the attached directions and warnings.
  • Page 12 Check the following before calling for servicing Problem Cause Solution Indoor unit does not operate when a • Is there a power outage? Turn off the operation button once, then button is pressed. turn it on again. • Is the circuit breaker on? If the circuit breaker is off, turn it on.
  • Page 13 The following symptoms does not indicate a malfunction Symptom Cause Unit does not operate immediately • Once the air conditioner is stopped, it will not be operated for approximately 3 when the air conditioner is restarted. minutes. This is to protect the unit. Sound of running water can be heard •...
  • Page 14: Specifications

    8.SPECIFICATIONS HEAT PUMP TYPE Capacity Range CS-W24BD2P CS-W28BD2P Indoor Single phase 220 240V CU-W24BBP5 CU-W28BBP5 Outdoor CS-W28BD2P CS-W34BD2P CS-W43BD2P CS-W50BD2P Indoor 3 phase, 4 lines 380 415V CU-W28BBP8 CU-W34BBP8 CU-W43BBP8 CU-W50BBP8 Outdoor 6.30 7.10 10.00 12.50 14.00 Cooling 21500 24200...
  • Page 15 WARNING 1) If the supply cord is damaged or needed to be replaced, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. 2) Turn off the circuit breaker before servicing this appliance. 3) Do not repair by yourself.
  • Page 16 Note Please remember to record the following: • Model Number • Serial Number • Dealer’s Name • Date Purchased – 15 –...