19 TWIN AND TRIPLE

19.1. Twin and Triple Operation
• • • • Simultaneous air conditioning of wide spaces and corners is
possible. Indoor units with different horsepowers can even
be used in combination.
19.1.1. Twin and triple operation setting
• • • • The master unit and slave units are set automatically when
the power is turned on. At this time, the indoor unit which is
connected to the remote control unit becomes the master
unit.
(If automatic setting is not possible, carry out the settings
manually.)
• • • • No distinction is made between master unit and slave units
(slave unit 1 and slave unit 2) at the indoor unit or remote
control.
• • • • Install the remote control to the master unit. (It cannot be
connected to slave units.)
If indoor unit models with louvres and models without
louvres have been connected together, use an indoor unit
• • • • Master unit and slave-units can be set automatically in twin
and triple systems. No address setting is necessary.
• • • • Multiple indoor units can be operated simultaneously with a
single remote control unit. Note that individual operation is
not possible.
with louvres as the master unit.
• • • • The remote control termostat can also be set.
• • • • Optional circuit boards can only be installed to the master
unit.
• • • • Setting the master unit and slave units can also be carried
out manually by using DIP switches. However, manual
settings will always take priority. If you have made manual
settings but would like to return to using automatic settings,
set all slave unit DIP switches (refer to the table below) to
the OFF position, and then press the ADDRESS RESET
button on the outdoor unit (SW3 on the outdoor unit printed
circuit board).
(Do not mix manual settings and automatic settings.)